Literature DB >> 8087828

Dynamic contrast-enhanced ultrasound with carbon dioxide microbubbles as adjunct to arteriography of liver tumors.

A Veltri1, S Capello, B Faissola, F Spalluto, S Farinet, M Grosso.   

Abstract

PURPOSE: The goal of the study is to evaluate utility of contrast-enhanced ultrasound (US) with carbon dioxide microbubbles in evaluation of hepatic lesions.
METHODS: Twenty-eight patients with single or multiple hepatic lesions (11 hepatocellular carcinoma, 8 hemangiomas, 5 metastases, 1 adenoma, 1 focal nodular hyperplasia, 2 regenerative nodules) were examined. US exam was performed during intraarterial injection of 10 ml of CO2 through the same catheter employed for liver arteriography. The US exam was videotaped in its salient phases. Characteristics of enhancement were evaluated and correlated with histological findings or patient follow-up.
RESULTS: Sonographic angiography clearly demonstrated vascularization of the lesions. Hepatocellular carcinoma, hemangioma, metastases, focal nodular hyperplasia, and regenerative nodules had very characteristic patterns. The injection of CO2 allowed detection of small additional nodules.
CONCLUSION: Sonographic angiography can improve characterization and staging of hepatic tumors. Low cost and the simplicity of the technique should encourage further experimentation.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8087828     DOI: 10.1007/bf00195505

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  14 in total

1.  SHU 508, a transpulmonary echocontrast agent: initial experience.

Authors:  T Fritzsch; J Hilmann; M Kämpfe; N Müller; C Schöbel; J Siegert
Journal:  Invest Radiol       Date:  1990-09       Impact factor: 6.016

2.  [Hepatic arterial lipiodolization and x-ray computed tomography diagnosis of malignant liver tumors. Experience apropos of 33 cases].

Authors:  J L Puech; H Rousseau; D Portalez; G Fourtanier; R Bugat; M H Marty; F Joffre
Journal:  Ann Radiol (Paris)       Date:  1987

3.  Gelatin encapsulated nitrogen microbubbles as ultrasonic contrast agents.

Authors:  B A Carroll; R J Turner; E G Tickner; D B Boyle; S W Young
Journal:  Invest Radiol       Date:  1980 May-Jun       Impact factor: 6.016

4.  Hepatic tumors: US contrast enhancement with CO2 microbubbles.

Authors:  Y Matsuda; I Yabuuchi
Journal:  Radiology       Date:  1986-12       Impact factor: 11.105

5.  Detection of focal hepatic masses: prospective evaluation with CT, delayed CT, CT during arterial portography, and MR imaging.

Authors:  J P Heiken; P J Weyman; J K Lee; D M Balfe; D Picus; E M Brunt; M W Flye
Journal:  Radiology       Date:  1989-04       Impact factor: 11.105

6.  Hepatic focal nodular hyperplasia: specific findings at dynamic contrast-enhanced US with carbon dioxide microbubbles.

Authors:  M Kudo; S Tomita; H Tochio; H Kashida; M Hirasa; A Todo
Journal:  Radiology       Date:  1991-05       Impact factor: 11.105

7.  Perfluoroctylbromide: a liver/spleen-specific and tumor-imaging ultrasound contrast material.

Authors:  R F Mattrey; F W Scheible; B B Gosink; G R Leopold; D M Long; C B Higgins
Journal:  Radiology       Date:  1982-12       Impact factor: 11.105

8.  Sonography with intraarterial infusion of carbon dioxide microbubbles (sonographic angiography): value in differential diagnosis of hepatic tumors.

Authors:  M Kudo; S Tomita; H Tochio; J Mimura; Y Okabe; H Kashida; M Hirasa; Y Ibuki; A Todo
Journal:  AJR Am J Roentgenol       Date:  1992-01       Impact factor: 3.959

9.  Ultrasonic contrast enhancement of tissue by encapsulated microbubbles.

Authors:  B A Carroll; S W Young; J S Rasor; R B Briller; D M Cassel
Journal:  Radiology       Date:  1982-06       Impact factor: 11.105

10.  Computed tomographic arteriography of the liver.

Authors:  P C Freeny; W M Marks
Journal:  Radiology       Date:  1983-07       Impact factor: 11.105

View more
  5 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV.

Authors:  Hanwook Park; Jun Hong Park; Sang Joon Lee
Journal:  Sci Rep       Date:  2016-11-28       Impact factor: 4.379

  5 in total