Literature DB >> 8074955

Analysis of scintigrams by singular value decomposition (SVD) technique.

S E Savolainen1, B K Liewendahl.   

Abstract

The singular value decomposition (SVD) method is presented as a potential tool for analyzing gamma camera images. Mathematically image analysis is a study of matrixes as the standard scintigram is a digitized matrix presentation of the recorded photon fluence from radioactivity of the object. Each matrix element (pixel) consists of a number, which equals the detected counts of the object position. The analysis of images can be reduced to the analysis of the singular values of the matrix decomposition. In the present study the clinical usefulness of SVD was tested by analyzing two different kinds of scintigrams: brain images by single photon emission tomography (SPET), and liver and spleen planar images. It is concluded that SVD can be applied to the analysis of gamma camera images, and that it provides an objective method for interpretation of clinically relevant information contained in the images. In image filtering, SVD provides results comparable to conventional filtering. In addition, the study of singular values can be used for semiquantitation of radionuclide images as exemplified by brain SPET studies and liver-spleen planar studies.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8074955     DOI: 10.1007/bf03165014

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  14 in total

1.  Improvement of Lesion Detection in Scintigraphic Images by SVD Techniques for Resolution Recovery.

Authors:  U Raff; D N Stroud; W R Hendee
Journal:  IEEE Trans Med Imaging       Date:  1986       Impact factor: 10.048

2.  Reconstruction of SPECT images using generalized matrix inverses.

Authors:  M F Smith; C R Floyd; R J Jaszczak; R E Coleman
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  Background correction in factor analysis of dynamic scintigraphic studies: necessity and implementation.

Authors:  M Van Daele; J Joosten; P Devos; A Vandecruys; J L Willems; M De Roo
Journal:  Phys Med Biol       Date:  1990-11       Impact factor: 3.609

4.  A comparison of liver-spleen ratios and uptakes obtained using planar and tomographic techniques.

Authors:  S T Chandler
Journal:  Nucl Med Commun       Date:  1989-04       Impact factor: 1.690

5.  An evaluation of four methods of 111In planar image quantification.

Authors:  A J van Rensburg; M G Lötter; A D Heyns; P C Minnaar
Journal:  Med Phys       Date:  1988 Nov-Dec       Impact factor: 4.071

6.  Quantitative evaluation and imaging of functions using pattern recognition methods.

Authors:  P Schmidlin
Journal:  Phys Med Biol       Date:  1979-03       Impact factor: 3.609

7.  Factor analysis in gated cardiac studies.

Authors:  F Cavailloles; J P Bazin; R Di Paola
Journal:  J Nucl Med       Date:  1984-10       Impact factor: 10.057

8.  Functional renal imaging through factor analysis.

Authors:  B E Oppenheim; C R Appledorn
Journal:  J Nucl Med       Date:  1981-05       Impact factor: 10.057

9.  The use of principal components in the quantitative analysis of gamma camera dynamic studies.

Authors:  D C Barber
Journal:  Phys Med Biol       Date:  1980-03       Impact factor: 3.609

10.  Diagnosis of acute herpes simplex encephalitis by brain perfusion single photon emission computed tomography.

Authors:  J Launes; P Nikkinen; L Lindroth; A L Brownell; K Liewendahl; M Iivanainen
Journal:  Lancet       Date:  1988-05-28       Impact factor: 79.321

View more
  1 in total

1.  Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids.

Authors:  H K Pohjonen; S E Savolainen; P H Nikkinen; V P Poutanen; E T Korppi-Tommola; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1996-11       Impact factor: 2.668