An evaluation of four methods of 111In planar image quantification.

A J van Rensburg1, M G Lötter, A D Heyns, P C Minnaar.   

Abstract

The accurate quantification of the in vivo distribution of 111In labeled platelets, other cells, and proteins with a scintillation camera is important in clinical and experimental medicine. Planar techniques of image quantification were therefore evaluated with the aim of improving on the accuracy, and simplifying the techniques currently in use. The attenuation of the 172- and 247-keV photons of 111In, singly and in combination, was determined for varying diameter flat sources (3.4 to 16.9 cm). The influence of region of interest (ROI) selection on the shape of the attenuation curves was also determined for five different ROI's. Defining the attenuation curves mathematically generated parameters of fit for three approaches to in vivo quantification, namely: a single exponential geometric mean approach that takes into account source size, depth-dependent, and depth-independent buildup factor approaches to account for the contribution of scatter. The accuracy of these techniques was ascertained and compared to the classical geometric mean method. This was done in a waxen phantom of a human thorax with a hollow liver and spleen. The results indicated that the depth-independent buildup factor is the best method; the error for quantification in the spleen was 0.8% +/- 2.2%. The classical geometric mean approach gave a corresponding error of 43.3% +/- 3.4%. Since the attenuation of the two energies of 111In differ, their ratio changes with depth. This phenomenon was investigated with the goal of determining whether the depth of an object can be estimated from one set of planar images. This was not successful.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3237142     DOI: 10.1118/1.596288

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

Review 1.  Anniversary paper: nuclear medicine: fifty years and still counting.

Authors:  Lawrence E Williams
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

2.  Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids.

Authors:  H K Pohjonen; S E Savolainen; P H Nikkinen; V P Poutanen; E T Korppi-Tommola; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1996-11       Impact factor: 2.668

3.  Attenuation correction of (111)In planar images by use of dual energy, fundamental study by Monte Carlo simulation.

Authors:  Seiji Shirakawa; Masanori Tadokoro; Hiroshi Hashimoto; Tomoya Ushiroda; Hiroshi Toyama
Journal:  Radiol Phys Technol       Date:  2014-08-23

4.  Comparison of non-invasive approaches to red marrow dosimetry for radiolabelled monoclonal antibodies.

Authors:  M A Plaizier; J C Roos; G J Teule; E B van Dieren; W den Hollander; H J Haisma; R L DeJager; A van Lingen
Journal:  Eur J Nucl Med       Date:  1994-03

5.  Quantification of technetium-99m lung radioactivity from planar images.

Authors:  N I Forge; P J Mountford; M J O'Doherty
Journal:  Eur J Nucl Med       Date:  1993-01

6.  Quantification of pulmonary uptake of indium-111 labelled granulocytes in inflammatory bowel disease.

Authors:  W Y Ussov; A M Peters; H J Hodgson; J M Hughes
Journal:  Eur J Nucl Med       Date:  1994-01

7.  Analysis of scintigrams by singular value decomposition (SVD) technique.

Authors:  S E Savolainen; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1994-05       Impact factor: 2.668

8.  A Quantitative Evaluation of Hepatic Uptake on I-131 Whole-Body Scintigraphy for Postablative Therapy of Thyroid Carcinoma.

Authors:  Michihiro Nakayama; Atsutaka Okizaki; Miki Sakaguchi; Shunta Ishitoya; Takahiro Uno; Junichi Sato; Koji Takahashi
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.889

  8 in total