Literature DB >> 8037088

Measurement of volumetric coronary blood flow by simultaneous intravascular two-dimensional and Doppler ultrasound: validation in an animal model.

T M Chou1, K Sudhir, S Iwanaga, K Chatterjee, P G Yock.   

Abstract

We examined the accuracy and feasibility of using simultaneous intracoronary Doppler and two-dimensional (2D) ultrasound imaging in the measurement of volumetric coronary blood flow (CBF). A femoral artery-to-circumflex coronary artery shunt was created in four dogs with tubing that incorporated an in-line transit-time ultrasound (TTU) flow probe. A 2D ultrasound catheter was introduced over a 0.014-inch Doppler guide wire into the circumflex artery with the guide wire tip positioned 2 cm beyond the imaging catheter tip. Cross-sectional area (CSA) and average peak velocity (APV) were recorded. CBF was determined from the previously validated relation CBF = CSA x 0.5 APV and the adjusted measurement formula CBF = CSA x 0.47 APV. Within the 119 measurements made, TTU CBF varied from 31 to 385 ml/min. An excellent correlation was found between 2D/Doppler-derived and TTU CBF with both constants; measurement agreement was improved and bias minimal with the 0.47 constant (slope = 0.9997; r = 0.99; p < 0.0001; SEE = -6.7 +/- 8.6). We conclude that simultaneous 2D and Doppler ultrasound yields accurate estimates of volumetric CBF.

Entities:  

Mesh:

Year:  1994        PMID: 8037088     DOI: 10.1016/0002-8703(94)90474-x

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  5 in total

1.  Effect of stenting on coronary flow velocity reserve: comparison of coil and tubular stents.

Authors:  C J Vrints; M J Claeys; J Bosmans; V Conraads; J P Snoeck
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  Post-stenotic coronary blood flow at rest is not altered by therapeutic doses of the oral antidiabetic drug glibenclamide in patients with coronary artery disease.

Authors:  T Reffelmann; H G Klues; P Hanrath; E R Schwarz
Journal:  Heart       Date:  2002-01       Impact factor: 5.994

Review 3.  Developments in cardiovascular ultrasound. Part 2: Arterial applications.

Authors:  P R Hoskins; P J Fish; W N McDicken; C Moran
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

Review 4.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

Review 5.  [Methods for coronary functional assessment].

Authors:  M Elsner
Journal:  Herz       Date:  1998-03       Impact factor: 1.443

  5 in total