Literature DB >> 8025574

Test-retest reliability of eccentric peak torque values for shoulder medial and lateral rotation using the Biodex isokinetic dynamometer.

S Frisiello1, A Gazaille, J O'Halloran, M L Palmer, D Waugh.   

Abstract

In order for the Biodex isokinetic dynamometer to be used in clinical research, it must be documented to be a reliable measurement tool. The purpose of this study was to determine eccentric peak torque test-retest reliability for glenohumeral medial and lateral rotator muscles using the Biodex isokinetic dynamometer. Eighteen healthy men and women volunteers ranging in ages from 18 to 30 who exhibited no prior history of glenohumeral injury were studied. The subjects were tested bilaterally for eccentric glenohumeral medial rotation (MR) and lateral rotation (LR) at 90 and 120 degrees/sec using 0 degrees of shoulder abduction so that the subject's arm was in contact with his or her trunk. Seven days following the initial test, a retest was administered using the identical protocol. Data collection of pretesting and posttesting was done using the IBM basic computer and the Biodex software program. Test data were analyzed using the intraclass correlation coefficient. The test-retest results indicated: dominant LR at 90 degrees/sec, r = 0.86, and at 120 degrees/sec, r = 0.83; dominant MR at 90 degrees/sec, r = 0.76, and at 120 degrees/sec, r = 0.77; nondominant LR at 90 degrees/sec, r = 0.76, and at 120 degrees/sec, r = 0.83; and nondominant MR at 90 degrees/sec, r = 0.75, and at 120 degrees/sec, r = 0.83. The results demonstrate the isokinetic eccentric mode of the Biodex dynamometer to be reliable for the test-retest measure of peak torque. These data may be used to support future clinical research of the eccentric isokinetic mode of the Biodex isokinetic dynamometer.

Entities:  

Mesh:

Year:  1994        PMID: 8025574     DOI: 10.2519/jospt.1994.19.6.341

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  7 in total

1.  INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

Authors:  Bryan L Riemann; Sarah E Davis; Kevin Huet; George J Davies
Journal:  Int J Sports Phys Ther       Date:  2016-02

2.  Objective assessment of shoulder mobility with a new 3D gyroscope--a validation study.

Authors:  Bilal Farouk El-Zayat; Turgay Efe; Annett Heidrich; Udo Wolf; Nina Timmesfeld; Thomas J Heyse; Stefan Lakemeier; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2011-07-21       Impact factor: 2.362

3.  The effects of complex decongestive therapy on pain and functionality in individuals with breast cancer who developed adhesive capsulitis due to lymphedema: an evaluation by an isokinetic computerized system.

Authors:  Konca Kaya Tatar; Begumhan Turhan
Journal:  Korean J Pain       Date:  2022-07-01

4.  Isokinetic peak torque ratios and shoulder injury history in adolescent female volleyball athletes.

Authors:  Christopher D Stickley; Ronald K Hetzler; Bret G Freemyer; Iris F Kimura
Journal:  J Athl Train       Date:  2008 Oct-Dec       Impact factor: 2.860

5.  Evaluating Postoperative Muscle Strength Using Surface Electromyography in Hip Fracture Patient.

Authors:  Jun-Il Yoo; Hayoung Byun; Hyeong Seop Kim; Yun Jeong Jang; Chang Han Lee
Journal:  J Bone Metab       Date:  2020-05-31

6.  Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope.

Authors:  Bilal Farouk El-Zayat; Turgay Efe; Annett Heidrich; Robert Anetsmann; Nina Timmesfeld; Susanne Fuchs-Winkelmann; Markus Dietmar Schofer
Journal:  BMC Musculoskelet Disord       Date:  2013-02-26       Impact factor: 2.362

7.  Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity.

Authors:  Dario Martinez-Garcia; Angela Rodriguez-Perea; Paola Barboza; David Ulloa-Díaz; Daniel Jerez-Mayorga; Ignacio Chirosa; Luis Javier Chirosa Ríos
Journal:  PeerJ       Date:  2020-10-27       Impact factor: 2.984

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.