INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

Bryan L Riemann1, Sarah E Davis1, Kevin Huet1, George J Davies1.   

Abstract

BACKGROUND: Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE).
PURPOSE: To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities.
METHODS: Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects.
RESULTS: High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p < .05) as velocity increased whereas AP increased as velocity increased. PF and AP during pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs.
CONCLUSION: Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and AP compared to pulling can be attributed to the muscles involved and the frequency that pushing patterns are used during functional activities. LEVEL OF EVIDENCE: 3.

Entities:  

Keywords:  Closed kinetic chain; power testing; strength testing; upper extremity

Year:  2016        PMID: 26900503      PMCID: PMC4739051     

Source DB:  PubMed          Journal:  Int J Sports Phys Ther        ISSN: 2159-2896


  14 in total

1.  Measures of reliability in sports medicine and science.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

2.  Test-retest reliability of glenohumeral internal and external rotator strength.

Authors:  Nadine A Plotnikoff; Donna L MacIntyre
Journal:  Clin J Sport Med       Date:  2002-11       Impact factor: 3.638

3.  Evaluation of isokinetic force production and associated muscle activity in the scapular rotators during a protraction-retraction movement in overhead athletes with impingement symptoms.

Authors:  A M Cools; E E Witvrouw; G A Declercq; G G Vanderstraeten; D C Cambier
Journal:  Br J Sports Med       Date:  2004-02       Impact factor: 13.800

4.  Reliability of shoulder rotators isokinetic strength imbalance measured using the Biodex dynamometer.

Authors:  Pascal Edouard; Philippe Codine; Pierre Samozino; Pierre-Louis Bernard; Christian Hérisson; Vincent Gremeaux
Journal:  J Sci Med Sport       Date:  2012-06-30       Impact factor: 4.319

5.  Shoulder muscle activity during pushing, pulling, elevation and overhead throw.

Authors:  Arpád Illyés; Rita M Kiss
Journal:  J Electromyogr Kinesiol       Date:  2005-06       Impact factor: 2.368

6.  Reliability of isokinetic and isometric knee-extensor force in older women.

Authors:  T Brock Symons; Anthony A Vandervoort; Charles L Rice; Tom J Overend; Greg D Marsh
Journal:  J Aging Phys Act       Date:  2004-10       Impact factor: 1.961

7.  Upper body push and pull strength ratio in recreationally active adults.

Authors:  Rodney J Negrete; William J Hanney; Patrick Pabian; Morey J Kolber
Journal:  Int J Sports Phys Ther       Date:  2013-04

8.  American College of Sports Medicine position stand. Quantity and quality of exercise for developing and maintaining cardiorespiratory, musculoskeletal, and neuromotor fitness in apparently healthy adults: guidance for prescribing exercise.

Authors:  Carol Ewing Garber; Bryan Blissmer; Michael R Deschenes; Barry A Franklin; Michael J Lamonte; I-Min Lee; David C Nieman; David P Swain
Journal:  Med Sci Sports Exerc       Date:  2011-07       Impact factor: 5.411

9.  Isokinetic scapular muscle performance in young elite gymnasts.

Authors:  Ann M Cools; Ellen Geerooms; Dorien F M Van den Berghe; Dirk C Cambier; Erik E Witvrouw
Journal:  J Athl Train       Date:  2007 Oct-Dec       Impact factor: 2.860

10.  Isokinetic and isometric measurement of strength of external rotation and abduction of the shoulder.

Authors:  J R Kuhlman; J P Iannotti; M J Kelly; F X Riegler; M L Gevaert; T M Ergin
Journal:  J Bone Joint Surg Am       Date:  1992-10       Impact factor: 5.284

View more
  2 in total

1.  A Study on sEMG-Based Motor Variability and Functional Connectivity of the Upper Limb Depending on Weight Distributions in a Handle of a Cordless Stick-Type Vacuum Cleaner.

Authors:  Hayeon Yu; Eunchae Kang; Joonho Chang
Journal:  Sensors (Basel)       Date:  2022-06-26       Impact factor: 3.847

Review 2.  Statistical Primer for Athletic Trainers: The Essentials of Understanding Measures of Reliability and Minimal Important Change.

Authors:  Bryan L Riemann; Monica R Lininger
Journal:  J Athl Train       Date:  2018-01-13       Impact factor: 2.860

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.