Literature DB >> 8023438

Modelling contrast sensitivity as a function of retinal illuminance and grating area.

J Rovamo1, J Mustonen, R Näsänen.   

Abstract

We extended the contrast detection model of human vision [Rovamo, Luntinen & Näsänen (1993b) Vision Research, 33, 2773-2788] to low light levels by taking into account the effect of light-dependent quantal noise. The extended model comprises (i) low-pass filtering due to the optical modulation transfer function of the eye, (ii) addition of light-dependent noise at the event of quantal absorption, (iii) high-pass filtering of neural origin (lateral inhibition), (iv) addition of internal neural noise, and (v) detection by a local matched filter whose efficiency decreases with increasing grating area. To test the model we measured foveal contrast sensitivity as a function of retinal illuminance and grating area at spatial frequencies of 0.125-32 c/deg. In agreement with the model, monocular contrast sensitivity at all grating areas increased in proportion to I when retinal illuminance (I) was smaller than critical illuminance. Thereafter the increase saturated and contrast sensitivity became independent of retinal illuminance. Similarly, at all levels of retinal illuminance contrast sensitivity increased in proportion to A when grating area (A) was smaller than critical area. Thereafter the increase saturated and contrast sensitivity became independent of area. Critical level of retinal illuminance increased in proportion to the spatial frequency squared. Critical area marking the saturation of spatial integration was constant at low spatial frequencies but decreased in inverse proportion to spatial frequency squared at medium and high spatial frequencies. The maximum contrast sensitivity obtainable by spatial integration in bright light increased at low spatial frequencies in proportion to spatial frequency, was constant at medium spatial frequencies, and decreased in inverse proportion to spatial frequency cubed at high spatial frequencies. The increase was due to the neural modulation transfer function of the visual pathways whereas the decrease was due to the optical modulation transfer function of the eye. The model explained 91-99% of the total variance of our contrast sensitivity data at various spatial frequencies.

Entities:  

Mesh:

Year:  1994        PMID: 8023438     DOI: 10.1016/0042-6989(94)90204-6

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  9 in total

1.  Mouse primary visual cortex is used to detect both orientation and contrast changes.

Authors:  Lindsey L Glickfeld; Mark H Histed; John H R Maunsell
Journal:  J Neurosci       Date:  2013-12-11       Impact factor: 6.167

2.  Suprathreshold Contrast Perception Is Altered by Long-term Adaptation to Habitual Optical Blur.

Authors:  Cherlyn J Ng; Ramkumar Sabesan; Antoine Barbot; Martin S Banks; Geunyoung Yoon
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-10-03       Impact factor: 4.925

3.  Transparency of the bovine corneal stroma at physiological hydration and its dependence on concentration of the ambient anion.

Authors:  Oksana Kostyuk; Oksana Nalovina; Turki M Mubard; Justyn W Regini; Keith M Meek; Andrew J Quantock; Gerald F Elliott; Stuart A Hodson
Journal:  J Physiol       Date:  2002-09-01       Impact factor: 5.182

4.  Contrast response functions in the visual wulst of the alert burrowing owl: a single-unit study.

Authors:  Pedro Gabrielle Vieira; João Paulo Machado de Sousa; Jerome Baron
Journal:  J Neurophysiol       Date:  2016-07-27       Impact factor: 2.714

5.  Contrast sensitivity of cats and humans in scotopic and mesopic conditions.

Authors:  Incheol Kang; Rachel E Reem; Amy L Kaczmarowski; Joseph G Malpeli
Journal:  J Neurophysiol       Date:  2009-05-20       Impact factor: 2.714

6.  Test-retest Repeatability of the Ohio Contrast Cards.

Authors:  Mawada Osman; Stevie M Njeru; Gregory R Hopkins; Angela M Brown
Journal:  Optom Vis Sci       Date:  2021-09-01       Impact factor: 2.106

7.  The Effect of Test Distance on Visual Contrast Sensitivity Measured Using the Pelli-Robson Chart.

Authors:  Stevie M Njeru; Mawada Osman; Angela M Brown
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

8.  Internal noise sources limiting contrast sensitivity.

Authors:  Daphné Silvestre; Angelo Arleo; Rémy Allard
Journal:  Sci Rep       Date:  2018-02-07       Impact factor: 4.379

9.  Resolution acuity across the visual field for mesopic and scotopic illumination.

Authors:  Michael O Wilkinson; Roger S Anderson; Arthur Bradley; Larry N Thibos
Journal:  J Vis       Date:  2020-10-01       Impact factor: 2.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.