The correction of coagulometer effects on international normalized ratios: a multicentre evaluation.

L Poller1, J M Thomson, D A Taberner, D K Clarke.   

Abstract

One hundred and twenty-nine centres in the U.K. participated in a study to test the reliability of the three methods of correction for coagulometer effects on international normalized ratios (INR). Results from 37 centres which tested three warfarinized plasmas by the manual method were taken as the 'true' INR for the assessment of coagulometers. 63 centres (11 manual and 52 using coagulometers) determined their local International Sensitivity Index (ISI) in a calibration exercise. This was performed with a set of 20 lyophilized plasma calibrants with certified manual prothrombin times for the thromboplastin used in the study. The following methods of INR derivation were compared by assessing the percentage deviation from the three INR values established by 37 manual users: I. No coagulometer correction, i.e. (local PT/reference manual normal PT)manual ISI II. Coagulometer ratio correction, i.e. (local coagulometer PT/local coagulometer MNPT)manual ISI III. Local system ISI, i.e. (local coagulometer PT/local coagulometer MNPT)local system ISI IV. System ISI, i.e. (local coagulometer PT/local coagulometer MNPT)system ISI The local system ISI with the plasma calibrants (method III) gave the most reliable correction (mean deviation from 'true' INR 4.87%). The method which gave the least was with the coagulometer ratio correction, i.e. the manual ISI and local coagulometer MNPT (mean 11.25%). The system ISI tested with ACL coagulometers gave less correction than the local ISI calibration. The local system calibration with lyophilized plasmas also avoids some of the constraints on conventional thromboplastin calibrations.

Mesh:

Substances:

Year:  1994        PMID: 8011518     DOI: 10.1111/j.1365-2141.1994.tb03260.x

Source DB:  PubMed          Journal:  Br J Haematol        ISSN: 0007-1048            Impact factor:   6.998


  5 in total

1.  Multicentre evaluation of the Thrombotest International Sensitivity Index used with a steel ball coagulometer.

Authors:  A M van den Besselaar; R H Peters
Journal:  J Clin Pathol       Date:  1996-05       Impact factor: 3.411

2.  Calculation of System International Sensitivity Index: how many calibrant plasmas are required?

Authors:  J M Dufty; S Craig; K J Stevenson; D A Taberner
Journal:  J Clin Pathol       Date:  1997-01       Impact factor: 3.411

Review 3.  Clinical utilization of the international normalized ratio (INR).

Authors:  R S Riley; D Rowe; L M Fisher
Journal:  J Clin Lab Anal       Date:  2000       Impact factor: 2.352

4.  The importance of "like to like" ISI calibrations with freeze dried plasmas. European Concerted Action on Anticoagulation.

Authors:  L Poller; A M van den Besselaar; J Jespersen; A Tripodi; D Houghton
Journal:  J Clin Pathol       Date:  1998-04       Impact factor: 3.411

Review 5.  Measurement of non-VKA oral anticoagulants versus classic ones: the appropriate use of hemostasis assays.

Authors:  Jonathan Douxfils; Anne Tamigniau; Bernard Chatelain; Catherine Goffinet; Jean-Michel Dogné; François Mullier
Journal:  Thromb J       Date:  2014-11-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.