Literature DB >> 7997588

Transient splenic inhomogeneity with contrast-enhanced CT: mechanism and effect of liver disease.

K A Miles1, S J McPherson, M P Hayball.   

Abstract

PURPOSE: To use computed tomography (CT) and functional imaging to characterize the physiologic processes that result in transient splenic inhomogeneity during contrast material enhancement and determine their value in detection of diffuse liver disease.
MATERIALS AND METHODS: CT scan data from nine control patients and 13 patients with diffuse liver disease were used to create functional images that displayed splenic perfusion and time to peak enhancement. A pixel-by-pixel analysis was used to create these images.
RESULTS: Areas of early enhancement demonstrated higher perfusion and vice versa. In patients with liver disease, splenic perfusion values fell from 1.44 to 1.22 mL/min/mL in the areas that showed early enhancement and 1.24 to 0.89 mL/min/mL in the areas that showed late enhancement. As splenic perfusion values fell, the size of the regions that showed late enhancement increased.
CONCLUSION: The combination of functional images and CT data has clarified the mechanism by which transient splenic inhomogeneity occurs and is of potential value in the detection of diffuse liver disease.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7997588     DOI: 10.1148/radiology.194.1.7997588

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Evaluation of flow measurement from the first pass bolus T1 weighted images using inversion recovery sequence.

Authors:  M Nazarpoor
Journal:  Br J Radiol       Date:  2010-10-19       Impact factor: 3.039

2.  Evaluation of the changes in signals from the spleen using ferucarbotran.

Authors:  Tatsuya Gomi; Masashi Nagamoto; Mika Tsunoo; Shigehiko Terada; Hitoshi Terada; Ehiichi Kohda
Journal:  Radiat Med       Date:  2007-04-27

3.  What is a reliable CT scan for diagnosing splenosis under emergency conditions?

Authors:  Francesco Giuseppe Garaci; Michele Grande; Massimo Villa; Stefano Mancino; Daniel Konda; Grazia Maria Attinà; Gabriele Galatà; Giovanni Simonetti
Journal:  World J Gastroenterol       Date:  2009-08-07       Impact factor: 5.742

4.  Unidentified bright objects of spleen on arterial phase CT: mimicker of splenic vascular injury in blunt abdominal trauma.

Authors:  Naren Hemachandran; Shivanand Gamanagatti; Raju Sharma; Atin Kumar; Amit Gupta; Subodh Kumar
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630

5.  Diffuse Infiltrative Splenic Lymphoma: Diagnostic Efficacy of Arterial-Phase CT.

Authors:  Jeong Eun Lee; June-Sik Cho; Kyung Sook Shin; Song Soo Kim; Sun Kyoung You; Jae Woo Park; Hye Soo Shin; Yeo Chang Yoon
Journal:  Korean J Radiol       Date:  2016-08-23       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.