Literature DB >> 17450339

Evaluation of the changes in signals from the spleen using ferucarbotran.

Tatsuya Gomi1, Masashi Nagamoto, Mika Tsunoo, Shigehiko Terada, Hitoshi Terada, Ehiichi Kohda.   

Abstract

PURPOSE: Because superparamagnetic iron oxide is actively taken into the reticuloendothelial system, the signal intensity observed on T2-weighted images is reduced not only in the liver but also in the spleen. There is no difference in the reduction in signal intensity in the liver after contrast between the ferumoxides and ferucarbotran, but the reduction in signal intensity in the spleen is considerable. In the present study, we examined the efficacy of T2*-weighted imaging to compensate for the reduction in signal intensity in the spleen by administering ferucarbotran.
MATERIALS AND METHODS: We examined the images obtained from 35 patients who underwent MRI with ferucarbotran. T2-weighted images and T2*-weighted images were obtained before and after administration of ferucarbotran, and the changes in signal intensity in the liver and spleen were then analyzed.
RESULTS: A reduction in signal intensity was observed in the liver by both T2- and T2*-weighted imaging. In the spleen, the signal intensity was reduced on T2-weighted images but was not reduced on T2*-weighted images.
CONCLUSION: The reduction in signal intensity due to administration of ferucarbotran is low in the spleen. Thus, it was considered necessary to approach the problem of diagnosing ectopic splenic tissue using ferucarbotran with caution.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17450339     DOI: 10.1007/s11604-006-0108-0

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  13 in total

1.  Detection of liver metastases with superparamagnetic iron oxide in 15 patients: results of MR imaging at 1.5 T.

Authors:  G Marchal; P Van Hecke; P Demaerel; E Decrop; C Kennis; A L Baert; E van der Schueren
Journal:  AJR Am J Roentgenol       Date:  1989-04       Impact factor: 3.959

2.  Transient splenic inhomogeneity with contrast-enhanced CT: mechanism and effect of liver disease.

Authors:  K A Miles; S J McPherson; M P Hayball
Journal:  Radiology       Date:  1995-01       Impact factor: 11.105

3.  Characterization of focal hepatic lesions with ferumoxides-enhanced MR imaging: utility of T1-weighted spoiled gradient recalled echo images using different echo times.

Authors:  Joo Hee Kim; Myeong-Jin Kim; Sang Hyun Suh; Jae-Joon Chung; Hyung Sik Yoo; Jong Tae Lee
Journal:  J Magn Reson Imaging       Date:  2002-05       Impact factor: 4.813

4.  MR imaging of the liver and spleen: a comparison of the effects on signal intensity of two superparamagnetic iron oxide agents.

Authors:  F Chen; J Ward; P J Robinson
Journal:  Magn Reson Imaging       Date:  1999-05       Impact factor: 2.546

5.  Intrahepatic splenosis: imaging features.

Authors:  S De Vuysere; W Van Steenbergen; R Aerts; H Van Hauwaert; D Van Beckevoort; L Van Hoe
Journal:  Abdom Imaging       Date:  2000 Mar-Apr

6.  MDCT and superparamagnetic iron oxide (SPIO)-enhanced MR findings of intrapancreatic accessory spleen in seven patients.

Authors:  Se Hyung Kim; Jeong Min Lee; Joon Koo Han; Jae Young Lee; Won Joon Kang; Jin Young Jang; Kyung-Sook Shin; Kyunghee C Cho; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2006-03-18       Impact factor: 5.315

7.  Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display.

Authors:  Taro Takahara; Yutaka Imai; Tomohiro Yamashita; Seiei Yasuda; Seiji Nasu; Marc Van Cauteren
Journal:  Radiat Med       Date:  2004 Jul-Aug

8.  Hepatic MR imaging with ferumoxides: a multicenter clinical trial of the safety and efficacy in the detection of focal hepatic lesions.

Authors:  P R Ros; P C Freeny; S E Harms; S E Seltzer; P L Davis; T W Chan; A E Stillman; L R Muroff; V M Runge; M A Nissenbaum
Journal:  Radiology       Date:  1995-08       Impact factor: 11.105

9.  Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver.

Authors:  D D Stark; R Weissleder; G Elizondo; P F Hahn; S Saini; L E Todd; J Wittenberg; J T Ferrucci
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

10.  Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: a comparative study using seven pulse sequences.

Authors:  Seung Hoon Kim; Dongil Choi; Jae Hoon Lim; Won Jae Lee; Hyun Jung Jang; Hyo Keun Lim; Soon Jin Lee; Jae Min Cho; Seung Kwon Kim; Gab Chul Kim
Journal:  Korean J Radiol       Date:  2002 Apr-Jun       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.