Literature DB >> 7994957

Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components.

S E White1, L A Whiteside, D S McCarthy, M Anthony, R A Poggie.   

Abstract

A knee simulator that mimics the plowing/rolling wear mechanisms of the knee was used to compare wear properties of cobalt chromium and oxidized zirconium femoral components. The simulator flexes and extends the knee so that the femoral components travels from 0 degrees to 30 degrees while applying axial loads from 130 to 1300 lb. Three oxidized zirconium and 3 cobalt chromium femoral components were tested with 10-mm tibial polyethylene components. The oxidized zirconium femoral components caused significantly less ultra high molecular weight polyethylene wear than cobalt chromium femoral components. Tibial inserts that were articulated against the cobalt chromium components had evidence of scratching, burnishing, and delamination, but none of the surfaces that were articulated against oxidized zirconium components had evidence of delamination. Cobalt chromium surface roughness significantly increased during the 2,000,000 cycle test, but oxidized zirconium surface roughness was not affected. Polyethylene wear was correlated to a significant degree with the surface roughness of the femoral components. The improved wear characteristics of the ceramic articular surfaces can be explained by the wettability of the ceramic surface, which minimized adhesive wear, and the resistance of the hard, ceramic surface to roughening.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7994957

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  The 5-year results of an oxidized zirconium femoral component for TKA.

Authors:  Massimo Innocenti; Roberto Civinini; Christian Carulli; Fabrizio Matassi; Marco Villano
Journal:  Clin Orthop Relat Res       Date:  2009-10-02       Impact factor: 4.176

Review 2.  Clinical Results of Oxidized Zirconium Femoral Component in TKA. A Review of Long-Term Survival: Review Article.

Authors:  Roberto Civinini; Fabrizio Matassi; Christian Carulli; Luigi Sirleo; Andrea Cozzi Lepri; Massimo Innocenti
Journal:  HSS J       Date:  2016-07-13

3.  Total knee arthroplasty in patients with hypersensitivity to metals.

Authors:  Massimo Innocenti; Christian Carulli; Fabrizio Matassi; Anna Maria Carossino; Maria Luisa Brandi; Roberto Civinini
Journal:  Int Orthop       Date:  2014-01-04       Impact factor: 3.075

4.  What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty?

Authors:  Christina M Arnholt; Daniel W MacDonald; Gregg R Klein; Harold E Cates; Clare M Rimnac; Steven M Kurtz; Sevi Kocagoz; Antonia F Chen
Journal:  J Arthroplasty       Date:  2018-05-17       Impact factor: 4.757

5.  The 2018 Mark Coventry, MD Award: Does a Ceramic Bearing Improve Pain, Function, Wear, or Survivorship of TKA in Patients Younger Than 55 Years of Age? A Randomized Trial.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

6.  Does oxidized zirconium make a difference? Midterm cohort survivorship of symmetric posterior condyle posterior-stabilized total knee arthroplasty

Authors:  A. Ross Demcoe; Eric R. Bohm; David R. Hedden; Colin D. Burnell; Thomas R. Turgeon
Journal:  Can J Surg       Date:  2019-04-01       Impact factor: 2.089

7.  Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Wansoo Huh; Kwang-Hoon Lee
Journal:  Clin Orthop Relat Res       Date:  2009-12-01       Impact factor: 4.176

8.  Oxidized zirconium versus cobalt-chromium in TKA: profilometry of retrieved femoral components.

Authors:  Thomas J Heyse; Marcella E Elpers; Danyal H Nawabi; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

9.  [Preclinical evaluation of coated knee implants for allergic patients].

Authors:  J Reich; L Hovy; H-L Lindenmaier; R Zeller; J Schwiesau; P Thomas; T M Grupp
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

10.  No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

Authors:  Yukihide Minoda; Kanako Hata; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Yusuke Hashimoto; Fumiaki Inori; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-20       Impact factor: 4.342

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.