Literature DB >> 7968855

Digitization requirements in mammography: effects on computer-aided detection of microcalcifications.

H P Chan1, L T Niklason, D M Ikeda, K L Lam, D D Adler.   

Abstract

We have developed a computerized method for detection of microcalcifications on digitized mammograms. The program has achieved an accuracy that can detect subtle microcalcifications which may potentially be missed by radiologists. In this study, we evaluated the dependence of the detection accuracy on the pixel size and pixel depth of the digitized mammograms. The mammograms were digitized with a laser film scanner at a pixel size of 0.035 mm x0.035 mm and 12-bit gray levels. Digitization with larger pixel sizes or fewer number of bits was simulated by averaging adjacent pixels or by eliminating the least significant bits, respectively. The SNR enhancement filter and the signal-extraction criteria in the computer program were adjusted to maximize the accuracy of signal detection for each pixel size. The overall detection accuracy was compared using the free response receiver operating characteristic curves. The results indicate that the detection accuracy decreases significantly as the pixel size increases from 0.035 mm x 0.035 mm to 0.07 mm x 0.07 mm (P < 0.007) and from 0.07 mm x 0.07 mm to 0.105 mm x 0.105 mm (P < 0.002). The detection accuracy is essentially independent of pixel depth from 12 to 9 bits and decreases significantly (P < 0.003) from 9 to 8 bits; a rapid decrease is observed as the pixel depth decreases further from 8 to 7 bits (P < 0.03) or from 7 to 6 bits (P < 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7968855     DOI: 10.1118/1.597354

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Computer-aided detection system for clustered microcalcifications: comparison of performance on full-field digital mammograms and digitized screen-film mammograms.

Authors:  Jun Ge; Lubomir M Hadjiiski; Berkman Sahiner; Jun Wei; Mark A Helvie; Chuan Zhou; Heang-Ping Chan
Journal:  Phys Med Biol       Date:  2007-01-23       Impact factor: 3.609

2.  Should previous mammograms be digitised in the transition to digital mammography?

Authors:  S Taylor-Phillips; M G Wallis; A G Gale
Journal:  Eur Radiol       Date:  2009-03-18       Impact factor: 5.315

3.  Mammographic image denoising and enhancement using the Anscombe transformation, adaptive wiener filtering, and the modulation transfer function.

Authors:  Larissa C S Romualdo; Marcelo A C Vieira; Homero Schiabel; Nelson D A Mascarenhas; Lucas R Borges
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

Review 4.  Teleradiology/telepathology requirements and implementation.

Authors:  S K Mun; A M Elsayed; W G Tohme; Y C Wu
Journal:  J Med Syst       Date:  1995-04       Impact factor: 4.460

5.  Computer-aided detection of pulmonary embolism in computed tomographic pulmonary angiography (CTPA): performance evaluation with independent data sets.

Authors:  Chuan Zhou; Heang-Ping Chan; Berkman Sahiner; Lubomir M Hadjiiski; Aamer Chughtai; Smita Patel; Jun Wei; Philip N Cascade; Ella A Kazerooni
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.