Literature DB >> 7968447

Avoiding peripheral nerve stimulation: gradient waveform criteria for optimum resolution in echo-planar imaging.

P R Harvey1, P Mansfield.   

Abstract

Adaptation of Mansfield and Harvey's theory of magnetically induced neural stimulation indicates that, for trapezoidal gradient waveforms and at the relatively low modulation frequencies commonly used in echo-planar imaging, an increase in rise time even to the point of creating a triangular waveform can prove advantageous over the use of simple sinusoidal modulation. For example, a higher image resolution is in principle possible before the neural stimulation limit is reached. For higher modulation frequencies and fast ramp trapezoidal waveforms, the peak gradient can be lower than that for a sinusoidal waveform by a factor approaching 2/pi for equal resolution. This means that by using a multimode resonant gradient drive, the amplifier power requirements are greatly relaxed. The signal sampling bandwidth required is also lower, because, due to the trapezoidal nonlinear sample pattern, sample points are spaced linearly during the waveform plateaus.

Mesh:

Year:  1994        PMID: 7968447     DOI: 10.1002/mrm.1910320213

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

Review 1.  The modular gradient coil: an holistic approach to power efficient and high performance whole-body MRI without peripheral nerve stimulation.

Authors:  P R Harvey; E Katznelson
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

2.  Effects of pulse duration on magnetostimulation thresholds.

Authors:  Emine U Saritas; Patrick W Goodwill; Steven M Conolly
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

3.  Magnetic Resonance Imaging with Composite (Dual) Gradients.

Authors:  Dennis L Parker; K Craig Goodrich; J Rock Hadley; Seong-Eun Kim; Sung M Moon; Blaine A Chronik; Ulrich Fontius; Franz Schmitt
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2009-04-01       Impact factor: 1.176

4.  Controlled E-field gradient coils.

Authors:  P Mansfield; R M Bowley; B Haywood
Journal:  MAGMA       Date:  2003-10-31       Impact factor: 2.310

5.  Combined acquisition technique (CAT) for neuroimaging of multiple sclerosis at low specific absorption rates (SAR).

Authors:  Armin Biller; Morwan Choli; Martin Blaimer; Felix A Breuer; Peter M Jakob; Andreas J Bartsch
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

  5 in total