Literature DB >> 7943926

Feasibility of a combined carrier test for disinfectants: studies with a mixture of five types of microorganisms.

M Best1, V S Springthorpe, S A Sattar.   

Abstract

BACKGROUND: There is mounting concern regarding the efficacy of many germicides on the market because officially recognized germicidal tests for various classes of microorganisms vary widely and often lack reproducibility and proper quantitation. We report here a carrier method for simultaneously and quantitatively assessing the efficacy of liquid chemical germicides against a mixture of microorganisms of varying degrees of resistance.
METHODS: In the test, each small glass cup (10 mm wide x 14 mm long) was contaminated with 10 microliters of a standardized mixture of Staphylococcus aureus, Mycobacterium bovis bacille Calmette-Guérin, Trichophyton mentagrophytes spores, Sabin poliovirus type 1, and Bacillus stearothermophilus spores in 5% fetal bovine serum. The inoculum was dried for 60 minutes under ambient conditions and covered with 60 microliters of the disinfectant under test or a balanced salt solution control for the desired contact time. The carrier was then placed in 2940 microliters of an eluent and the eluates assayed separately for the five microorganisms. Tap water was used to dilute the test product as needed.
RESULTS: Of the 11 products tested, 2% alkaline glutaraldehyde, 0.6% sodium hypochlorite (about 5000 ppm free chlorine), and a 0.4% quarternary ammonium compound containing 23% hydrochloric acid were effective against all five challenge organisms. A hard-surface spray containing 0.1% o-phenylphenol with 79% ethanol was effective against all but bacterial spores; 70% (volume/volume) ethanol alone and povidone-iodine (1% available iodine) were effective against S. aureus, the mycobacterium, and the fungus; a 3% solution of peroxygen compounds was effective only against S. aureus and the poliovirus; 1.5% chlorhexidine gluconate, 0.06% quaternary ammonia compound, and 0.03% o-phenylphenol + 0.03% p-tertiary amylphenol could inactivate nothing but S. aureus; and 3% hydrogen peroxide was ineffective in all tests.
CONCLUSIONS: This method shows promise for use with various classes of microorganisms, individually or as mixtures. Its application should enable the classification of germicides according to spectrum of activity.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7943926     DOI: 10.1016/0196-6553(94)90004-3

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  12 in total

Review 1.  Quaternary ammonium biocides: efficacy in application.

Authors:  Charles P Gerba
Journal:  Appl Environ Microbiol       Date:  2014-10-31       Impact factor: 4.792

2.  Value of the chlorhexidine decontamination method for recovery of nontuberculous mycobacteria from sputum samples of patients with cystic fibrosis.

Authors:  Agnès Ferroni; Hoang Vu-Thien; Philippe Lanotte; Muriel Le Bourgeois; Isabelle Sermet-Gaudelus; Brigitte Fauroux; Sophie Marchand; Françoise Varaigne; Patrick Berche; Jean-Louis Gaillard; Catherine Offredo
Journal:  J Clin Microbiol       Date:  2006-06       Impact factor: 5.948

3.  The effect of sterilization methods on the physical properties of silk sericin scaffolds.

Authors:  Tippawan Siritientong; Teerapol Srichana; Pornanong Aramwit
Journal:  AAPS PharmSciTech       Date:  2011-06-14       Impact factor: 3.246

4.  Factors in the Selection of Surface Disinfectants for Use in a Laboratory Animal Setting.

Authors:  Michael V Campagna; Emmanuelle Faure-Kumar; Janet A Treger; Jesse D Cushman; Tristan R Grogan; Noriyuki Kasahara; Gregory W Lawson
Journal:  J Am Assoc Lab Anim Sci       Date:  2016-03       Impact factor: 1.232

5.  Rapid screening method for Mycobactericidal activity of chemical germicides that uses Mycobacterium terrae expressing a green fluorescent protein gene.

Authors:  A A Zafer; Y E Taylor; S A Sattar
Journal:  Appl Environ Microbiol       Date:  2001-03       Impact factor: 4.792

Review 6.  Epidemiologic background of hand hygiene and evaluation of the most important agents for scrubs and rubs.

Authors:  Günter Kampf; Axel Kramer
Journal:  Clin Microbiol Rev       Date:  2004-10       Impact factor: 26.132

7.  Influence of temperature and organic load on chemical disinfection of Geobacillus steareothermophilus spores, a surrogate for Bacillus anthracis.

Authors:  Jiewen Guan; Maria Chan; Brian W Brooks; Liz Rohonczy
Journal:  Can J Vet Res       Date:  2013-04       Impact factor: 1.310

8.  The Effect of Sterilization Methods on the Structural and Chemical Properties of Fibrin Microthread Scaffolds.

Authors:  Jonathan M Grasman; Megan P O'Brien; Kevin Ackerman; Keith A Gagnon; Gregory M Wong; George D Pins
Journal:  Macromol Biosci       Date:  2016-02-04       Impact factor: 4.979

Review 9.  Antiseptics and disinfectants: activity, action, and resistance.

Authors:  G McDonnell; A D Russell
Journal:  Clin Microbiol Rev       Date:  1999-01       Impact factor: 26.132

10.  Broad-spectrum microbicidal activity, toxicologic assessment, and materials compatibility of a new generation of accelerated hydrogen peroxide-based environmental surface disinfectant.

Authors:  Navid Omidbakhsh; Syed A Sattar
Journal:  Am J Infect Control       Date:  2006-06       Impact factor: 2.918

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.