Literature DB >> 7940150

Validity of pulsatile ocular blood flow measurements.

D M Silver1, R A Farrell.   

Abstract

The determination of average net pulsatile ocular blood flow form measurements of the intraocular pressure (IOP) pulse is based upon 1) an accurate measurement of IOP and its time variation; 2) a knowledge of the relation between the volume of the living eye and its IOP; 3) a physical model for the flow of blood through the eye: and 4) a concept of steady venous outflow from the eye. Each of these premises needs to be examined. The present analysis assesses the validity of the pneumatic tonometer for measuring the pressure in a flowing column of gas that is directed toward a thin membrane that is in contact with the surface of the cornea. The pressure of this stream of gas exerts a force against the cornea that depresses the corneal surface against the opposing force of the IOP. The balance of these forces and the resultant effect on the tonometer pressure sensor is described by the theories of elasticity, thermodynamics and fluid mechanics. In this treatment, differential equations are solved for the elastic deflections of the cornea subject to the opposing intraocular and tonometer pressures. This permits the pressure in the chamber of the pneumatic tonometer to be related through first principles to the IOP. The response of the tonometer pressure sensor to a range of IOPs (5-60 mmHg) is obtained, as well as the dynamical response of the tonometer to IOP oscillations. The conclusion is that the pneumatic tonometer provides a high fidelity, noninvasive measure of the IOP and its time variation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7940150     DOI: 10.1016/0039-6257(94)90049-3

Source DB:  PubMed          Journal:  Surv Ophthalmol        ISSN: 0039-6257            Impact factor:   6.048


  24 in total

1.  Pulsatile ocular blood flow in asymmetric exudative age related macular degeneration.

Authors:  S J Chen; C Y Cheng; A F Lee; F L Lee; J C Chou; W M Hsu; J H Liu
Journal:  Br J Ophthalmol       Date:  2001-12       Impact factor: 4.638

2.  Intraocular pressure and pulsatile ocular blood flow after retrobulbar and peribulbar anaesthesia.

Authors:  R Watkins; B Beigi; M Yates; B Chang; E Linardos
Journal:  Br J Ophthalmol       Date:  2001-07       Impact factor: 4.638

3.  Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects.

Authors:  E Polska; K Polak; A Luksch; G Fuchsjager-Mayrl; V Petternel; O Findl; L Schmetterer
Journal:  Br J Ophthalmol       Date:  2004-04       Impact factor: 4.638

4.  Effects of phacoemulsification surgery on ocular hemodynamics.

Authors:  Adem Turk; Suleyman Mollamehmetoglu; Halil Ibrahim Imamoglu; Mehmet Kola; Hidayet Erdol; Nurettin Akyol
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

5.  The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.

Authors:  P-A Tonnu; T Ho; T Newson; A El Sheikh; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

6.  Non-invasive vascular impedance measures demonstrate ocular vasoconstriction during isometric exercise.

Authors:  Andrew J Morgan; Sarah L Hosking
Journal:  Br J Ophthalmol       Date:  2006-10-18       Impact factor: 4.638

7.  Pulsatile ocular blood flow: relationship with flow velocities in vessels supplying the retina and choroid.

Authors:  Itay Ben Zion; Alon Harris; Brent Siesky; Shiri Shulman; Lynne McCranor; Hanna J Garzozi
Journal:  Br J Ophthalmol       Date:  2007-07       Impact factor: 4.638

Review 8.  Cellular and physiological mechanisms underlying blood flow regulation in the retina and choroid in health and disease.

Authors:  Joanna Kur; Eric A Newman; Tailoi Chan-Ling
Journal:  Prog Retin Eye Res       Date:  2012-05-03       Impact factor: 21.198

9.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

10.  Unrecordable pulsatile ocular blood flow may signify severe stenosis of the ipsilateral internal carotid artery.

Authors:  Y Barkana; A Harris; L Hefez; M Zaritski; D Chen; I Avni
Journal:  Br J Ophthalmol       Date:  2003-12       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.