Literature DB >> 7935202

Feasibility of dual radionuclide brain imaging with I-123 and Tc-99m.

M Ivanovic1, D A Weber, S Loncaric, D Franceschi.   

Abstract

A study was conducted to evaluate the feasibility of simultaneous dual radionuclide brain imaging with 123I and 99mTc using photopeak image subtraction techniques or offset photopeak image acquisition. The contribution of the photons from one radionuclide to a second radionuclide's photopeak energy window (crosstalk) was evaluated for SPECT and planar imaging of a brain phantom containing 123I and 99mTc for a range of activity levels and distribution properties approximating those in rCBF images of the adult human brain. Crosstalk was evaluated for 10% symmetrical energy windows centered on the 123I and 99mTc photopeaks and for 10% energy windows asymmetrically placed to the left and right of the center of the respective photopeaks. Major observations include: (1) in the centered photopeak windows, 99mTc crosstalk in the 123I window is 8.9% of the 99mTc seen in the 99mTc window and ranges from 37.5% to 75.0% of the 123I in the 123I window. 123I crosstalk is 37.8% of the 123I seen in the 123I window and ranges from 4.4% to 8.9% of the 99mTc seen in the 99mTc window; (2) the spatial distribution of a radionuclide's crosstalk photons differs from that observed in the radionuclide's photopeak window; (3) a 99mTc photopeak window offset to the left does not decrease 123I crosstalk, and the percentage of 99mTc scattered photons is significantly increased in the window.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7935202     DOI: 10.1118/1.597320

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

Review 1.  Brain single-photon emission CT physics principles.

Authors:  R Accorsi
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-26       Impact factor: 3.825

2.  Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT.

Authors:  Yong Du; Eric C Frey
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  Simultaneous dual-radionuclide imaging: are the images trustworthy?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1996-10

4.  Optimal collimator choice for sequential iodine-123 and technetium-99m imaging.

Authors:  F D Geeter; P R Franken; M Defrise; H Andries; E Saelens; A Bossuyt
Journal:  Eur J Nucl Med       Date:  1996-07

5.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.