Literature DB >> 7929769

Development of o.a.s.i.s., a new automated blood culture system in which detection is based on measurement of bottle headspace pressure changes.

C M Stevens1, D Swaine, C Butler, A H Carr, A Weightman, C R Catchpole, D E Healing, T S Elliott.   

Abstract

o.a.s.i.s. (Unipath Ltd., Basingstoke, United Kingdom) is a new automated blood culture system. The metabolism of microorganisms is detected by measuring changes in the pressure of the headspace of blood culture bottles. These changes are measured by monitoring the position of a flexible sealing septum, every 5 min, with a scanning laser sensor. This noninvasive system can detect both gas absorption and production and does not rely solely on measuring increasing carbon dioxide levels. A research prototype instrument was used to carry out an evaluation of the media, the detection system, and its associated detection algorithm. In simulated blood cultures, o.a.s.i.s. supported growth and detected a range of clinical isolates. Times to positivity were significantly shorter in o.a.s.i.s. than in the BACTEC 460 system. Results of a clinical feasibility study, with a manual blood culture system as a control, confirmed that o.a.s.i.s. was able to support the growth and detection of a variety of clinically significant organisms. On the basis of these findings, full-scale comparative clinical trials of o.a.s.i.s. with other automated blood culture systems are warranted.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7929769      PMCID: PMC263784          DOI: 10.1128/jcm.32.7.1750-1756.1994

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Comparison of Sentinel and Bactec blood culture systems.

Authors:  M Stevens; H Patel; A Walters; K Burch; A Jay; N Dowling; C J Mitchell; R A Swann; A T Willis; D C Shanson
Journal:  J Clin Pathol       Date:  1992-09       Impact factor: 3.411

2.  BioArgos: a fully automated blood culture system.

Authors:  R J Courcol; M Duhamel; A Decoster; V M Lemaire; M L Rastorgoueff; D Ochin; G R Martin
Journal:  J Clin Microbiol       Date:  1992-08       Impact factor: 5.948

3.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

4.  Gelatin neutralization of the inhibitory effect of sodium polyanethol sulfonate on Neisseria meningitidis in blood culture media.

Authors:  J Eng; E Holten
Journal:  J Clin Microbiol       Date:  1977-07       Impact factor: 5.948

5.  Novel method for detecting micro-organisms in blood cultures.

Authors:  D Sawhney; S Hinder; D Swaine; E Y Bridson
Journal:  J Clin Pathol       Date:  1986-11       Impact factor: 3.411

Review 6.  Blood cultures: an overview.

Authors:  J A Washington
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

Review 7.  World-wide development of antibiotic resistance in pneumococci.

Authors:  P C Appelbaum
Journal:  Eur J Clin Microbiol       Date:  1987-08       Impact factor: 3.267

8.  Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240).

Authors:  F S Nolte; J M Williams; R C Jerris; J A Morello; C D Leitch; S Matushek; L D Schwabe; F Dorigan; F E Kocka
Journal:  J Clin Microbiol       Date:  1993-03       Impact factor: 5.948

9.  Detection of bacteremia by Difco ESP blood culture system.

Authors:  J A Morello; C Leitch; S Nitz; J W Dyke; M Andruszewski; G Maier; W Landau; M A Beard
Journal:  J Clin Microbiol       Date:  1994-03       Impact factor: 5.948

10.  Blood for culture.

Authors:  T S Elliott; C R Catchpole; D E Healing
Journal:  Lancet       Date:  1993 Dec 18-25       Impact factor: 79.321

View more
  7 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Controlled Evaluation of the New BacT/Alert Virtuo Blood Culture System for Detection and Time to Detection of Bacteria and Yeasts.

Authors:  Osman Altun; Mohammed Almuhayawi; Petra Lüthje; Rubina Taha; Måns Ullberg; Volkan Özenci
Journal:  J Clin Microbiol       Date:  2016-02-03       Impact factor: 5.948

3.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

4.  Use of prototype automated blood culture system and gas-liquid chromatography for the analysis of continuous ambulatory peritoneal dialysis associated infection.

Authors:  C R Catchpole; F Macrae; J D Brown; M Palmer; D E Healing; N T Richards; T S Elliott
Journal:  J Clin Pathol       Date:  1997-03       Impact factor: 3.411

Review 5.  Microbiological and clinical aspects of infection associated with Stenotrophomonas maltophilia.

Authors:  M Denton; K G Kerr
Journal:  Clin Microbiol Rev       Date:  1998-01       Impact factor: 26.132

6.  Continuous quality improvement for introduction of automated blood culture instrument.

Authors:  M Alfa; S Sanche; S Roman; Y Fiola; P Lenton; G Harding
Journal:  J Clin Microbiol       Date:  1995-05       Impact factor: 5.948

7.  Considerations in evaluating equipment-free blood culture bottles: A short protocol for use in low-resource settings.

Authors:  Sien Ombelet; Alessandra Natale; Jean-Baptiste Ronat; Olivier Vandenberg; Jan Jacobs; Liselotte Hardy
Journal:  PLoS One       Date:  2022-04-25       Impact factor: 3.752

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.