Literature DB >> 1500505

BioArgos: a fully automated blood culture system.

R J Courcol1, M Duhamel, A Decoster, V M Lemaire, M L Rastorgoueff, D Ochin, G R Martin.   

Abstract

BioArgos (Sanofi Diagnostics Pasteur, Marnes-la-Coquette, France) is a fully automated blood culture system that detects carbon dioxide production by infrared spectroscopy through a glass bottle. This hands-off system was compared with the BACTEC NR-660 system (Becton Dickinson Diagnostic Instrument Systems, Towson, Md.). A total of 336 microorganisms belonging to 74 taxa were tested in simulated blood cultures by both systems. Experimental data showed no significant differences between the two systems. The inclusive detection times (+/- the standard deviations) were 33.2 +/- 28.7 and 35.0 +/- 30.6 h with BioArgos and BACTEC, respectively. Anaerobes were detected earlier with BioArgos, whereas detection of some organisms that need oxygen to grow was slightly delayed. In conclusion, BioArgos is as reliable and accurate as BACTEC NR-660 and shows better practicability owing to noninvasive detection, reduction of vial manipulation, and absence of daily maintenance.

Entities:  

Mesh:

Year:  1992        PMID: 1500505      PMCID: PMC265430          DOI: 10.1128/jcm.30.8.1995-1998.1992

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

2.  Early detection of bacterial growth, with carbon-14-labeled glucose.

Authors:  F H DeLand; H N Wagner
Journal:  Radiology       Date:  1969-01       Impact factor: 11.105

3.  Routine evaluation of the nonradiometric BACTEC NR 660 system.

Authors:  R J Courcol; A Fruchart; M Roussel-Delvallez; G R Martin
Journal:  J Clin Microbiol       Date:  1986-07       Impact factor: 5.948

4.  Bioluminescent measurement of ATP for the rapid detection of positive blood cultures.

Authors:  B Beckers; H R Lang
Journal:  Naturwissenschaften       Date:  1982-03

5.  Automated radiometric detection of bacteria in 2,967 blood cultures.

Authors:  H J DeBlanc; F DeLand; H N Wagner
Journal:  Appl Microbiol       Date:  1971-11

6.  Rapid diagnosis of bacteremia.

Authors:  S M Finegold; M L White; I Ziment; W R Winn
Journal:  Appl Microbiol       Date:  1969-09

7.  [Usefulness of micro-organism counts in positive haemocultures (author's transl)].

Authors:  J M Mantz; J P Faller; A Le Faou; A Jaeger; R Minck
Journal:  Nouv Presse Med       Date:  1981 Jul 11-25

8.  Sodium polyanethol sulfonate sensitivity of anaerobic cocci.

Authors:  M H Graves; J A Morello; F E Kocka
Journal:  Appl Microbiol       Date:  1974-06
  8 in total
  4 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Detection kinetics for positive blood culture bottles by using the VITAL automated system.

Authors:  H Marchandin; B Compan; M Simeon De Buochberg; E Despaux; C Perez
Journal:  J Clin Microbiol       Date:  1995-08       Impact factor: 5.948

3.  Development of o.a.s.i.s., a new automated blood culture system in which detection is based on measurement of bottle headspace pressure changes.

Authors:  C M Stevens; D Swaine; C Butler; A H Carr; A Weightman; C R Catchpole; D E Healing; T S Elliott
Journal:  J Clin Microbiol       Date:  1994-07       Impact factor: 5.948

4.  Nosocomial and community-acquired spontaneous bacterial peritonitis: comparative microbiology and therapeutic implications.

Authors:  F Bert; M Andreu; F Durand; F Degos; J-O Galdbart; R Moreau; C Branger; N Lambert-Zechovsky; D Valla
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2003-01-29       Impact factor: 3.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.