Literature DB >> 7922071

Reducing the risk of viral transmission at operation by electronic monitoring of the surgeon-patient barrier.

I M Macintyre1, J S Currie, D N Smith, I D Anderson, R Cadossi.   

Abstract

A new electronic device designed to detect glove holes, wet gowns and glove permeability was assessed during 50 general surgical operations. The cause of each alarm was recorded and the surgeon's awareness of any breach noted. Some 266 alarms were recorded of which 45 were ascribed to glove holes, 86 to wet gowns, 115 to glove porosity and 20 to other causes. Glove holes occurred in 29 of the 50 procedures; the surgeon was unaware of the hole in almost 70 per cent of cases. Holes were more common in laparotomy than in laparoscopic procedures (P = 0.006). In 20 per cent of instances surgeons did not respond immediately to the alarm (median delay 16 min). Six of eight surgeons who used the device indicated that they would do so regularly for major abdominal surgery. The electronic system accurately detects breaches in the surgeon-patient barrier. Its use should improve surgical discipline in acting to restore the barrier, protecting patient and surgeon alike.

Entities:  

Mesh:

Year:  1994        PMID: 7922071     DOI: 10.1002/bjs.1800810752

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  5 in total

1.  Inadvertent prolonged fluid contact: an unappreciated professional risk for surgeons.

Authors:  J L Caillot; C Cote; E Voiglio; J Fabry
Journal:  Eur J Epidemiol       Date:  2000       Impact factor: 8.082

2.  The protective efficacy of surgical latex gloves against the risk of skin contamination: how well are the operators protected?

Authors:  R V Hentz; G C Traina; R Cadossi; P Zucchini; M A Muglia; M Giordani
Journal:  J Mater Sci Mater Med       Date:  2000-12       Impact factor: 3.896

3.  Randomized clinical trial comparing blunt tapered and standard needles in closing abdominal fascia.

Authors:  Rob A G Nordkam; Simone J M Bluyssen; Harry van Goor
Journal:  World J Surg       Date:  2005-04       Impact factor: 3.352

4.  How should the chest wall be opened at necropsy?

Authors:  J E C Walker; G N Rutty; B Rodgers; N W F Woodford
Journal:  J Clin Pathol       Date:  2002-01       Impact factor: 3.411

5.  Surgeon-patient barrier efficiency monitored with an electronic device in three surgical settings.

Authors:  V R Hentz; M Stephanides; A Boraldi; R Tessari; R Isani; R Cadossi; R Biscione; L Massari; G C Traina
Journal:  World J Surg       Date:  2001-09       Impact factor: 3.352

  5 in total