Literature DB >> 11825931

How should the chest wall be opened at necropsy?

J E C Walker1, G N Rutty, B Rodgers, N W F Woodford.   

Abstract

AIMS: To compare several different instruments used to open the chest wall during necropsy and to assess whether any one type reduced the production of sharp rib ends and thus the potential for receiving an injury.
METHODS: During the necropsy the pathologist opened the chest wall using two randomly assigned instruments from a selection of hand saw, electric saw, rib shears, and bread knife. The age, weight, sex, and height of the deceased were recorded, in addition to the textures of the resultant exposed rib ends. During the procedure, the speed, length, production of spray, and site of incision were also noted. The thoracic cavity was inspected and any details of tumours, adhesions, fluid, or organ damage were noted.
RESULTS: Twenty four necropsies were carried out on an equal number of men and women. The total number of ribs that were incised was 422, with 206 through the bony aspect (49%). Sixty seven per cent of the bony rib ends were rough, and this was found to be instrument dependent. The rib shears produced the highest number of rough bony and cartilage rib ends. The electric saw produced the smoothest contoured rib ends. Spray occurred in 29% of cases, exclusively with the use of the electric saw. Organ damage was most frequently associated with the use of the bread knife.
CONCLUSION: Rib shears, the instrument most frequently used to open the chest wall, appear to cause the highest frequency of rough, potentially dangerous rib ends. The electric saw produced the smoothest rib ends, both in cartilage and bone, and thus seems to offer the most efficacious method of reducing the potential hazard associated with ragged, spiky bone ends during the opening of the thoracic cavity. Although each of the procedures detailed in this study was shown to have its own advantages and disadvantages, personal preference and operator experience are perhaps the most important factors in ultimately determining the method used.

Entities:  

Mesh:

Year:  2002        PMID: 11825931      PMCID: PMC1769557          DOI: 10.1136/jcp.55.1.72

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  4 in total

1.  A 51-year retrospective study of the trends of height, weight and body mass index at the time of death in those aged 16-103.

Authors:  H Woodward; J E Rutty; G N Rutty
Journal:  J Clin Forensic Med       Date:  2001-06

2.  Efficacy of double gloving with a coloured inner pair for immediate detection of operative glove perforations.

Authors:  J J Duron; K Keilani; N G Elian
Journal:  Eur J Surg       Date:  1996-12

3.  Electronic device for the detection of breaches in asepsis during surgical procedures.

Authors:  A J Hamer
Journal:  Br J Surg       Date:  1987-11       Impact factor: 6.939

4.  Reducing the risk of viral transmission at operation by electronic monitoring of the surgeon-patient barrier.

Authors:  I M Macintyre; J S Currie; D N Smith; I D Anderson; R Cadossi
Journal:  Br J Surg       Date:  1994-07       Impact factor: 6.939

  4 in total
  2 in total

Review 1.  Health and safety at necropsy.

Authors:  J L Burton
Journal:  J Clin Pathol       Date:  2003-04       Impact factor: 3.411

2.  Videos have a role in postgraduate necropsy education.

Authors:  J L Burton; G Diercks-O'Brien; G N Rutty
Journal:  J Clin Pathol       Date:  2004-08       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.