Literature DB >> 7919645

Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique.

B Jeanneret1, J S Gebhard, F Magerl.   

Abstract

Articular mass fracture-separation accounts for 9% of the fractures of the lower cervical spine. Neurologic complications are frequent and are usually radicular in nature. Unreduced, these fractures may cause persistent neck pain. The treatment is usually surgical, fusing two or three vertebrae. In this article we present a new treatment modality using reduction and stabilization of the dislocated fragment with a transpedicular lag screw. Previous anatomic studies have shown that the pedicles of the lower cervical spine are wide enough to accept 4.0-mm screws. An anatomic study was performed showing that transpedicular screw fixation is safe when the following technique is used: entry point 3 mm beneath the facet joint on a vertical line in the middle of the articular mass. The drill is angled medially, depending on the preoperative measurement on the computed tomography scan (average 45 degrees). The drill aims toward the cranial third of the vertebral body as seen on lateral fluoroscopy. The tap-drilling method is used. After placement of 33 screws in cadaver pedicles of the cervical spine, 10 had minor breakout of the cortex of the pedicle (only small parts of the threads were penetrating the cortex); none showed major violation of the pedicle wall. The most common direction of minor pedicle violation was lateral. Transpedicular screw fixation has been successfully used in three patients.

Entities:  

Mesh:

Year:  1994        PMID: 7919645     DOI: 10.1097/00002517-199407030-00004

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  43 in total

1.  Cervical pedicle screw insertion using a gutter entry point at the transitional area between the lateral mass and lamina.

Authors:  Katsuhiro Tofuku; Hiroaki Koga; Setsuro Komiya
Journal:  Eur Spine J       Date:  2011-08-10       Impact factor: 3.134

2.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

Review 3.  Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature.

Authors:  M Reinhold; C Bach; L Audigé; R Bale; R Attal; M Blauth; F Magerl
Journal:  Eur Spine J       Date:  2008-01-22       Impact factor: 3.134

4.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

5.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

6.  Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope.

Authors:  Yasutsugu Yukawa; Fumihiko Kato; Keigo Ito; Yumiko Horie; Tetsurou Hida; Hiroaki Nakashima; Masaaki Machino
Journal:  Eur Spine J       Date:  2009-06-02       Impact factor: 3.134

7.  An analysis of the anatomic features of the cervical spine using computed tomography to select safer screw insertion techniques.

Authors:  Masahiro Nishinome; Haku Iizuka; Yoichi Iizuka; Kenji Takagishi
Journal:  Eur Spine J       Date:  2013-07-06       Impact factor: 3.134

8.  Anatomic basis of anterior and posterior instrumentation of the spine: morphometric study.

Authors:  Bashar Abuzayed; Banu Tutunculer; Baris Kucukyuruk; Saffet Tuzgen
Journal:  Surg Radiol Anat       Date:  2009-08-21       Impact factor: 1.246

9.  The ipsilateral lamina-pedicle angle: can it be used to guide pedicle screw placement in the sub-axial cervical spine?

Authors:  Edward Bayley; Zergham Zia; Robert Kerslake; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2009-09-01       Impact factor: 3.134

10.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.