Literature DB >> 7863826

Comparison of radiographic absorptiometry with dual-energy x-ray absorptiometry and quantitative computed tomography in normal older white and black women.

M Kleerekoper1, D A Nelson, M J Flynn, A S Pawluszka, G Jacobsen, E L Peterson.   

Abstract

Bone mineral density (BMD) of the phalanges of the hand was measured by the technique of radiographic absorptiometry (RA) in 199 older postmenopausal women previously determined to have normal BMD by dual-energy x-ray absorptiometry (DXA) and quantitative computed tomography (QCT). The average age of the women was 66.8 +/- 4.9 years, and they were 19.9 +/- 6.7 years postmenopause. In the 54 black women, phalangeal BMD was 11.7% greater than in the 145 white women, a difference comparable to that found using DXA at the radial midshaft, the lumbar spine, and femoral neck. A correlation matrix comparing BMD measured by RA to BMD measured by DXA and QCT indicates that, in general, RA was related to the various DXA and QCT measurement sites as well as these sites were related to each other. When results for RA, DXA, and QCT obtained in our cohort of older women were compared to available reference data for peak adult bone mass, the average difference (SD units) from peak value was greatest for RA (-1.77 radius, -1.24 spine, -2.13 femoral neck, -2.34 QCT spine, and -2.71 phalanges). We conclude that RA is an acceptable measure of phalangeal BMD and that the data in our cohort can serve as reference data for older white and black women aged 55-75 years. Once the ability of RA to predict future fracture occurrence has been demonstrated, it could be rapidly deployed as a low-cost, widely available bone mass measurement technique.

Entities:  

Mesh:

Year:  1994        PMID: 7863826     DOI: 10.1002/jbmr.5650091111

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  14 in total

1.  Peak bone mineral density at the hip is linked to chromosomes 14q and 15q.

Authors:  Munro Peacock; Daniel L Koller; Siu Hui; C Conrad Johnston; Tatiana Foroud; Michael J Econs
Journal:  Osteoporos Int       Date:  2004-03-16       Impact factor: 4.507

2.  Ultrasound transmission velocity of the proximal phalanxes of the non-dominant hand in the study of osteoporosis.

Authors:  A Sili Scavalli; M Marini; A Spadaro; D Messineo; A Cremona; F Sensi; V Riccieri; E Taccari
Journal:  Clin Rheumatol       Date:  1997-06       Impact factor: 2.980

3.  Osteoporosis case finding in the general practice: phalangeal radiographic absorptiometry with and without risk factors for osteoporosis to select postmenopausal women eligible for lumbar spine and hip densitometry.

Authors:  Katharina M Gasser; Christian Mueller; Marcel Zwahlen; Manfred Kaufmann; Gaby Fuchs; Romain Perrelet; Gilbert Abetel; Ulrich Bürgi; Kurt Lippuner
Journal:  Osteoporos Int       Date:  2005-02-12       Impact factor: 4.507

4.  Computed radiographic absorptiometry and morphometry in the assessment of postmenopausal bone loss.

Authors:  S Adami; N Zamberlan; D Gatti; C Zanfisi; V Braga; M Broggini; M Rossini
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

5.  Radiographic absorptiometry for measuring bone mass.

Authors:  P D Ross
Journal:  Osteoporos Int       Date:  1997       Impact factor: 4.507

6.  Quantitative ultrasound of the hand phalanges in a cohort of monozygotic twins: influence of genetic and environmental factors.

Authors:  G Guglielmi; F de Terlizzi; I Torrente; R Mingarelli; B Dallapiccola
Journal:  Skeletal Radiol       Date:  2005-07-06       Impact factor: 2.199

7.  Three-year longitudinal study with quantitative ultrasound at the hand phalanx in a female population.

Authors:  R Mele; G Masci; V Ventura; D de Aloysio; M Bicocchi; R Cadossi
Journal:  Osteoporos Int       Date:  1997       Impact factor: 4.507

Review 8.  The role of ultrasound in the assessment of osteoporosis: a review.

Authors:  C F Njeh; C M Boivin; C M Langton
Journal:  Osteoporos Int       Date:  1997       Impact factor: 4.507

9.  Comparison of bone densitometry of the phalanges, distal forearm and axial skeleton in early postmenopausal women participating in the EPIC Study.

Authors:  P Ravn; K Overgaard; C Huang; P D Ross; D Green; M McClung
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

10.  Pathways of transmission of ultrasound energy through the distal metaphysis of the second phalanx of pigs: an in vitro study.

Authors:  R Cadossi; V Canè
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.