Literature DB >> 7824724

T2-weighted breath-hold MR imaging of the liver at 1.5 T: results with a three-dimensional steady-state free precession sequence in 87 patients.

M Taupitz1, A Speidel, B Hamm, M Deimling, M Reichel, A Bock, K J Wolf.   

Abstract

PURPOSE: To evaluate a fast three-dimensional (3D) sequence that permits the acquisition of 16 T2-weighted images within a 29-second breath hold for magnetic resonance (MR) imaging of the liver.
MATERIALS AND METHODS: Eighty-seven patients with focal liver lesions were examined at 1.5 T by using a 3D reversed fast imaging with steady-state precession (PSIF) sequence at flip angles of 15 degrees, 30 degrees, and 70 degrees and a T2-weighted spin-echo (SE) sequence. Quantitative and qualitative image analysis was performed.
RESULTS: Contrast and signal difference-to-noise ratios were 56% and 33% (liver-spleen) and 76% and 68% (liver-tumor), respectively, with the 3D-PSIF sequence compared with the T2-weighted SE sequence. With 3D-PSIF, overall image quality was poorer than that of the T2-weighted SE sequence at flip angles of 15 degrees but was similar at 30 degrees and 70 degrees. At low flip angles (15 degrees and 30 degrees) all lesion types were hyperintense. At a flip angle of 70 degrees, it was predominantly cysts and hemangiomas that showed high signal intensity. With the 3D-PSIF sequence, intrahepatic vessels are void of signal and can be better distinguished from small liver lesions compared with the flow-compensated T2-weighted SE sequence.
CONCLUSION: The fast 3D-PSIF sequence is a valuable addition to MR imaging of the liver.

Entities:  

Mesh:

Year:  1995        PMID: 7824724     DOI: 10.1148/radiology.194.2.7824724

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging.

Authors:  T K Helmberger; J Schröder; N Holzknecht; M Gregor; A Heuck; R Petsch; M F Reiser
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

2.  High-resolution diffusion-weighted MR imaging of the human lumbosacral plexus and its branches based on a steady-state free precession imaging technique at 3T.

Authors:  Z W Zhang; L J Song; Q F Meng; Z P Li; B N Luo; Y H Yang; Z Pei
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-13       Impact factor: 3.825

3.  Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning-based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence.

Authors:  Krishna Shanbhogue; Angela Tong; Paul Smereka; Dominik Nickel; Simon Arberet; Rebecca Anthopolos; Hersh Chandarana
Journal:  Eur Radiol       Date:  2021-05-07       Impact factor: 5.315

4.  Reevaluation of T2-weighted fast field echo (T2FFE): application to rapid volumetric black-blood imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Takashi Namiki; Atsushi Takemura; Makoto Obara
Journal:  Radiol Phys Technol       Date:  2013-02-16

5.  High-resolution MRI of the intraparotid facial nerve based on a microsurface coil and a 3D reversed fast imaging with steady-state precession DWI sequence at 3T.

Authors:  J Chu; Z Zhou; G Hong; J Guan; S Li; L Rao; Q Meng; Z Yang
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-11       Impact factor: 3.825

6.  A high-resolution fast spin-echo inversion-recovery sequence for preoperative localization of the internal globus pallidus.

Authors:  C A Reich; P A Hudgins; S K Sheppard; P A Starr; R A Bakay
Journal:  AJNR Am J Neuroradiol       Date:  2000-05       Impact factor: 4.966

7.  Diagnostic Value and Surgical Implications of the 3D DW-SSFP MRI On the Management of Patients with Brachial Plexus Injuries.

Authors:  Ben-Gang Qin; Jian-Tao Yang; Yi Yang; Hong-Gang Wang; Guo Fu; Li-Qiang Gu; Ping Li; Qing-Tang Zhu; Xiao-Lin Liu; Jia-Kai Zhu
Journal:  Sci Rep       Date:  2016-10-26       Impact factor: 4.379

8.  Comparison Between Three-Dimensional Diffusion-Weighted PSIF Technique and Routine Imaging Sequences in Evaluation of Peripheral Nerves in Healthy People.

Authors:  Mahsa Zare; Fariborz Faeghi; Ashrafsadat Hosseini; Mohammad Sobhan Ardekani; Mohammad Hossein Heidari; Ehsan Zarei
Journal:  Basic Clin Neurosci       Date:  2018 Jan-Feb

9.  N-acetylcysteine decreases lactate signal intensities in liver tissue and improves liver function in septic shock patients, as shown by magnetic resonance spectroscopy: extended case report.

Authors:  Ortrud Vargas Hein; Renate Ohring; Andreas Schilling; Michael Oellerich; Victor W Armstrong; Wolfgang J Kox; Claudia Spies
Journal:  Crit Care       Date:  2004-01-22       Impact factor: 9.097

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.