Literature DB >> 7824723

Comparison of breath-hold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions.

J N Rydberg1, D J Lomas, K J Coakley, D M Hough, R L Ehman, S J Riederer.   

Abstract

PURPOSE: To evaluate a breath-hold fast spin-echo (SE) technique for T2-weighted magnetic resonance (MR) imaging of liver lesions.
MATERIALS AND METHODS: A fast SE technique was developed that enabled six sections to be imaged per 16-second breath hold with a single echo. Resulting images were compared with those obtained with the first echo of a conventional dual-echo T2-weighted SE sequence (16 minutes 55 seconds for 18 sections). Thirty-one patients with malignant focal hepatic lesions were studied prospectively. The images were compared quantitatively and qualitatively.
RESULTS: Quantitatively, the contrast and contrast-to-noise ratios for the fast SE images were 20% +/- 5 and 19% +/- 8 greater, respectively, than those for the conventional T2-weighted SE images of the 54 representative lesions. Qualitatively, fast SE images had less image artifact, enabled comparable or better lesion sizing, and greatly improved depiction of extrahepatic structures compared with conventional T2-weighted SE images.
CONCLUSION: The fast SE technique with breath holding provides diagnostically useful liver images in a greatly decreased acquisition time.

Entities:  

Mesh:

Year:  1995        PMID: 7824723     DOI: 10.1148/radiology.194.2.7824723

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging.

Authors:  T K Helmberger; J Schröder; N Holzknecht; M Gregor; A Heuck; R Petsch; M F Reiser
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

2.  Preliminary experience with a new double-echo half-Fourier single-shot turbo spin echo acquisition in the characterization of liver lesions.

Authors:  H Bosmans; S Gryspeerdt; L Van Hoe; S Van Oostende; T De Jaegere; B Kiefer; A L Baert; G Marchal
Journal:  MAGMA       Date:  1997-03       Impact factor: 2.310

3.  Breath-hold MR imaging of focal liver lesions: comparison of fast and ultrasound techniques.

Authors:  J Gaa; H Fischer; G Laub; M Georgi
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Breathhold multiecho fast spin-echo pulse sequence for accurate R2 measurement in the heart and liver.

Authors:  Daniel Kim; Jens H Jensen; Ed X Wu; Sujit S Sheth; Gary M Brittenham
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

5.  A high-resolution fast spin-echo inversion-recovery sequence for preoperative localization of the internal globus pallidus.

Authors:  C A Reich; P A Hudgins; S K Sheppard; P A Starr; R A Bakay
Journal:  AJNR Am J Neuroradiol       Date:  2000-05       Impact factor: 4.966

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.