Literature DB >> 7817826

Dual x-ray absorptiometry forearm software: accuracy and intermachine relationship.

S Hagiwara1, K Engelke, S O Yang, M S Dhillon, G Guglielmi, D L Nelson, H K Genant.   

Abstract

An ash study was performed to analyze the accuracy of forearm measurements at the one-third site of three dual x-ray absorptiometry (DXA) systems using 20 cadavers. A Hologic QDR-2000, a Hologic QDR-1000/W, and a Lunar DPX-L system were used. The correlations between ash weight and DXA BMC were excellent for the three instruments (r > 0.97, p < 0.001), with accuracy errors < 5.2%. To perform a forearm cross-calibration of bone mineral content (BMC) and density (BMD) between the scanners, 10 healthy volunteers were additionally scanned at the distal one-third radius. The correlations among the DXA machines were excellent (r > 0.95); the absolute BMC and BMD values were significantly different between the two Hologics and the Lunar machine. The slope and intercept of both the BMC and BMD between the two Hologic systems were close to unity. In conclusion, the DXA forearm software packages provide accurate methods for assessing bone mineral content and density. The conversion of data among different manufacturers should be performed by careful cross-calibration measurements.

Entities:  

Mesh:

Year:  1994        PMID: 7817826     DOI: 10.1002/jbmr.5650090914

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  5 in total

1.  Radial bone density and breast cancer risk in white and African-American women.

Authors:  D A Nelson; L L Darga; M S Simon; R K Severson
Journal:  Osteoporos Int       Date:  2004-07       Impact factor: 4.507

Review 2.  [Absorptiometry].

Authors:  S Prevrhal
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

3.  Accuracy and precision study in vitro for peripheral quantitative computed tomography.

Authors:  M Takada; K Engelke; S Hagiwara; S Grampp; H K Genant
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

4.  Bone mineral density in vocational and professional ballet dancers.

Authors:  T Amorim; Y Koutedakis; A Nevill; M Wyon; J Maia; J C Machado; F Marques; G S Metsios; A D Flouris; N Adubeiro; L Nogueira; L Dimitriou
Journal:  Osteoporos Int       Date:  2017-06-27       Impact factor: 4.507

5.  Bone mass of female dance students prior to professional dance training: A cross-sectional study.

Authors:  Tânia Amorim; George S Metsios; Matthew Wyon; Alan M Nevill; Andreas D Flouris; José Maia; Eduardo Teixeira; José Carlos Machado; Franklim Marques; Yiannis Koutedakis
Journal:  PLoS One       Date:  2017-07-05       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.