Hemodynamic monitoring: invasive techniques.

N Buchbinder, W Ganz.   

Abstract

Mesh:

Year:  1976        PMID: 779528     DOI: 10.1097/00000542-197608000-00005

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


× No keyword cloud information.
  16 in total

Review 1.  Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care.

Authors:  Karim Bendjelid; Jacques-A Romand
Journal:  Intensive Care Med       Date:  2003-01-21       Impact factor: 17.440

2.  A new closed-system using partially frozen injectate for thermodilution cardiac output determinations.

Authors:  H Maruta; Y Usuda; Y Okutsu; K Numata
Journal:  J Anesth       Date:  1989-03-01       Impact factor: 2.078

Review 3.  Pulmonary hypertension with left-sided heart disease.

Authors:  Marco Guazzi; Ross Arena
Journal:  Nat Rev Cardiol       Date:  2010-10-05       Impact factor: 32.419

4.  What value does the recording of intrathoracic blood volume have in clinical practice?

Authors:  G Hedenstierna
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

5.  Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation.

Authors:  M Lichtwarck-Aschoff; J Zeravik; U J Pfeiffer
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

Review 6.  Right ventricle in acute and chronic pulmonary embolism (2013 Grover Conference series).

Authors:  Christian Gerges; Nika Skoro-Sajer; Irene M Lang
Journal:  Pulm Circ       Date:  2014-09       Impact factor: 3.017

7.  Increased pulmonary artery diastolic-pulmonary wedge pressure gradient after cardiopulmonary bypass.

Authors:  J Heinonen; M Salmenperä; O Takkunen
Journal:  Can Anaesth Soc J       Date:  1985-03

8.  Absence of right superior vena cava that was not detected by insertion of a pulmonary arterial catheter via the right internal jugular vein.

Authors:  Y Hara; K Ota; M Fujita; H Suzuki
Journal:  J Clin Monit       Date:  1994-05

9.  Microcomputer-based respiratory function monitoring system using impedence pneumography.

Authors:  A Itoh; A Ishida; N Kikuchi; N Okazaki; Y Kuratomi; T Ishihara; S Kira
Journal:  Med Biol Eng Comput       Date:  1982-09       Impact factor: 2.602

10.  Hemodynamic monitoring: catheter insertion techniques, complications and trouble-shooting.

Authors:  R S Baigrie; C D Morgan
Journal:  Can Med Assoc J       Date:  1979-10-06       Impact factor: 8.262