A new closed-system using partially frozen injectate for thermodilution cardiac output determinations.

H Maruta1, Y Usuda, Y Okutsu, K Numata.   

Abstract

The FI (partially frozen injectate) system, a new closed-system devised by the authors for thermodilution cardiac output determinations, has two major features: 1) it needs no ice-filled receptacle to keep injectate cold because it uses partially frozen injectate, and 2) it can go without monitoring the injectate temperatures during the whole process of cardiac output determinations. The author evaluated the accuracy and reproducibility of cardiac output determinations with the FI system in 10 critically ill patients, as compared with another closed-system (which is commercially available) and the standard open method. The injectate temperatures in the FI system were also measured in vitro. The mean injectate temperature in the FI system was 0.71 +/- 0.26 degrees C and 80% of the injectate temperatures were lower than 1.0 degrees C. Even when no monitoring of injectate temperatures was made, the predicated error in the calculated cardiac output resulted as low as 2% with the FI system. The mean cardiac output values were not statistically different between the FI system and the other two systems.

Entities:  

Year:  1989        PMID: 15236053     DOI: 10.1007/s0054090030035

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  12 in total

Review 1.  Current concepts measurement of cardiac output by thermodilution.

Authors:  R D Weisel; R L Berger; H B Hechtman
Journal:  N Engl J Med       Date:  1975-03-27       Impact factor: 91.245

Review 2.  Hemodynamic monitoring: invasive techniques.

Authors:  N Buchbinder; W Ganz
Journal:  Anesthesiology       Date:  1976-08       Impact factor: 7.892

3.  Effect of injectate volume and temperature on thermodilution cardiac output determination.

Authors:  R G Pearl; M H Rosenthal; L Nielson; J P Ashton; B W Brown
Journal:  Anesthesiology       Date:  1986-06       Impact factor: 7.892

Review 4.  Measurement of blood flow by thermodilution.

Authors:  W Ganz; H J Swan
Journal:  Am J Cardiol       Date:  1972-02       Impact factor: 2.778

5.  Limitations of thermal dilution curves for cardiac output determinations.

Authors:  H U Wessel; M H Paul; G W James; A R Grahn
Journal:  J Appl Physiol       Date:  1971-05       Impact factor: 3.531

6.  Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibility.

Authors:  J H Stevens; T A Raffin; F G Mihm; M H Rosenthal; C W Stetz
Journal:  JAMA       Date:  1985-04-19       Impact factor: 56.272

7.  Thermodilution cardiac output determination in hypothermic postcardiac surgery patients: room vs ice temperature injectate.

Authors:  F G Shellock; M S Riedinger; T M Bateman; R J Gray
Journal:  Crit Care Med       Date:  1983-08       Impact factor: 7.598

8.  Comparison of two closed systems for thermodilution cardiac outputs.

Authors:  J R Plachetka; D F Larson; N W Salomon; J G Copeland
Journal:  Crit Care Med       Date:  1981-06       Impact factor: 7.598

9.  Multiple cardiac output measurements in man. Evaluation of a new closed-system thermodilution method.

Authors:  J J Stawicki; F D Holford; E L Michelson; M E Josephson
Journal:  Chest       Date:  1979-08       Impact factor: 9.410

10.  Thermodilution cardiac output studies as a cause of prosthetic valve bacterial endocarditis.

Authors:  G M Stiles; L Singh; G Imazaki; Q R Stiles
Journal:  J Thorac Cardiovasc Surg       Date:  1984-12       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.