Literature DB >> 7792491

Assessment of accuracy and analysis time of a novel device to monitor sleep and breathing in the home.

D P White1, T J Gibb, J M Wall, P R Westbrook.   

Abstract

Obstructive sleep apnea is increasingly recognized as a common and debilitating disorder. As a result, a variety of diagnostic technologies have evolved to potentially decrease cost and improve access and ease of assessment. In this study we compared the Healthdyne NightWatch (NW) System (a home sleep diagnostic methodology) to standard polysomnography (PSG) in two sleep centers. Two separate studies were completed. NW was compared to a simultaneously obtained PSG in 30 patients (IN-LAB study). Seventy additional patients were studied in both the home with NW and in the laboratory with PSG (HOME-LAB study). The NW system records eye movement, leg movement, SaO2, nasal-oral airflow, chest and abdominal wall motion, body position and heart rate on a solid state recorder, which permits sleep staging based on body and eye movement and standard respiratory assessment. For the PSG, standard paper recording techniques were used. The IN-LAB study revealed a correlation between NW and PSG for total sleep time of r = 0.72, with NW tending to score some awake time as nonrapid eye movement sleep. The correlation for apnea-hypopnea index (AHI) was r = 0.94 between systems, with a sensitivity of 100% and specificity of 63.6% at an AHI threshold of 10. The HOME-LAB study demonstrated understandably poor correlations between NW and PSG for most measures of sleep, which is likely a product of night-to-night variability in sleep, home versus laboratory effects and the differences in sleep staging methodology. However, the correlation for AHI was r = 0.92, with a sensitivity of 90.7% and a specificity of 70.4% at an AHI threshold of 10. Using a new methodology to assess agreement between diagnostic systems, we observed 78.6% diagnostic agreement between NW and PSG in the HOME-LAB study, with NW underestimating AHI 4.3% of the time and overestimating it in 17.1% of cases. This may relate to night-to-night variability in AHI or greater NW computer sensitivity to subtle hypopneas. We conclude that NW provides an accurate determination of AHI in both the home and laboratory, using limited instrumentation. The analysis time for NW is also reduced compared to PSG, and patients generally prefer the NW evaluation.

Entities:  

Mesh:

Year:  1995        PMID: 7792491     DOI: 10.1093/sleep/18.2.115

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  22 in total

1.  Obstructive sleep apnea syndrome in a publicly funded healthcare system.

Authors:  Dana Tran; Jeanne Wallace
Journal:  J Natl Med Assoc       Date:  2005-03       Impact factor: 1.798

2.  Pre-eclampsia is associated with sleep-disordered breathing and endothelial dysfunction.

Authors:  D Yinon; L Lowenstein; S Suraya; R Beloosesky; O Zmora; A Malhotra; G Pillar
Journal:  Eur Respir J       Date:  2006-02       Impact factor: 16.671

3.  Drowsiness/alertness algorithm development and validation using synchronized EEG and cognitive performance to individualize a generalized model.

Authors:  Robin R Johnson; Djordje P Popovic; Richard E Olmstead; Maja Stikic; Daniel J Levendowski; Chris Berka
Journal:  Biol Psychol       Date:  2011-03-17       Impact factor: 3.251

4.  Use of home sleep studies for diagnosis of the sleep apnoea/hypopnoea syndrome.

Authors:  A T Whittle; S P Finch; I L Mortimore; T W MacKay; N J Douglas
Journal:  Thorax       Date:  1997-12       Impact factor: 9.139

5.  Diagnostic accuracy of home-based monitoring system in morbidly obese patients with high risk for sleep apnea.

Authors:  Márcia G Oliveira; Erika C Treptow; Cesar Fukuda; Luiz E Nery; Rosana M Valadares; Sérgio Tufik; Lia Bittencourt; Sonia M Togeiro
Journal:  Obes Surg       Date:  2015-05       Impact factor: 4.129

6.  Signal failure of type 2 comprehensive unattended sleep studies in patients with suspected respiratory sleep disordered breathing.

Authors:  Ahmed S BaHammam
Journal:  Sleep Breath       Date:  2005-03       Impact factor: 2.816

7.  Diagnostic performance of single airflow channel recording (ApneaLink) in home diagnosis of sleep apnea.

Authors:  Regine Ragette; Yi Wang; Gerhard Weinreich; Helmut Teschler
Journal:  Sleep Breath       Date:  2009-08-28       Impact factor: 2.816

8.  Assessment of a portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea.

Authors:  Li Weimin; Wang Rongguang; Huang Dongyan; Liu Xiaoli; Jin Wei; Yang Shiming
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-05-25       Impact factor: 2.503

9.  Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation.

Authors:  Stephen D Pittman; Najib T Ayas; Mary M MacDonald; Atul Malhotra; Robert B Fogel; David P White
Journal:  Sleep       Date:  2004-08-01       Impact factor: 5.849

10.  Validation of a portable monitoring system for the diagnosis of obstructive sleep apnea syndrome.

Authors:  Rogerio Santos-Silva; Denis E Sartori; Viviane Truksinas; Eveli Truksinas; Fabiana F F D Alonso; Sergio Tufik; Lia R A Bittencourt
Journal:  Sleep       Date:  2009-05       Impact factor: 5.849