Literature DB >> 15785915

Signal failure of type 2 comprehensive unattended sleep studies in patients with suspected respiratory sleep disordered breathing.

Ahmed S BaHammam1.   

Abstract

We designed this study to assess the signal failure and sensor loss of unattended type 2 comprehensive polysomnography (PSG) and compared that with in-lab attended PSG. Type 2 PSG was performed for 41 patients. The signal failure was estimated and compared to the signal failure in 60 patients for the in-lab PSGs. The signal failure in each individual electroencephalographic (EEG) channel, complete EEG signals, electro-oculography (EOG), naso-oral flow, and thoracic belt were significantly greater in the unattended sleep studies. The failure rate for the different signals ranged from 0.128 min in electrocardiography (EKG) to 67.36 min in the thoracic belt signal. However, that did not affect the success rate of the studies. Acceptable scorable data was available in 97% of the performed unattended PSGs. Unattended type 2 sleep studies can be performed for clinical use in the evaluation of sleep disordered breathing with low signal failure and sensor loss if the proper hook-up procedure was followed.

Entities:  

Mesh:

Year:  2005        PMID: 15785915     DOI: 10.1007/s11325-005-0001-6

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  11 in total

1.  EEG arousals: scoring rules and examples: a preliminary report from the Sleep Disorders Atlas Task Force of the American Sleep Disorders Association.

Authors: 
Journal:  Sleep       Date:  1992-04       Impact factor: 5.849

2.  Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome.

Authors:  F Portier; A Portmann; P Czernichow; L Vascaut; E Devin; D Benhamou; A Cuvelier; J F Muir
Journal:  Am J Respir Crit Care Med       Date:  2000-09       Impact factor: 21.405

3.  Use of home sleep studies for diagnosis of the sleep apnoea/hypopnoea syndrome.

Authors:  A T Whittle; S P Finch; I L Mortimore; T W MacKay; N J Douglas
Journal:  Thorax       Date:  1997-12       Impact factor: 9.139

4.  Evaluation of sleep disordered breathing with unattended recording: the Nightwatch System.

Authors:  S Ancoli-Israel; W Mason; T V Coy; C Stepnowsky; J L Clausen; J Dimsdale
Journal:  J Med Eng Technol       Date:  1997 Jan-Feb

Review 5.  Portable recording in the assessment of obstructive sleep apnea. ASDA standards of practice.

Authors:  R Ferber; R Millman; M Coppola; J Fleetham; C F Murray; C Iber; W V McCall; G Nino-Murcia; M Pressman; M Sanders
Journal:  Sleep       Date:  1994-06       Impact factor: 5.849

6.  Rates of sensor loss in unattended home polysomnography: the influence of age, gender, obesity, and sleep-disordered breathing.

Authors:  V K Kapur; D M Rapoport; M H Sanders; P Enright; J Hill; C Iber; J Romaniuk
Journal:  Sleep       Date:  2000-08-01       Impact factor: 5.849

7.  Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults.

Authors:  Andrew L Chesson; Richard B Berry; Allan Pack
Journal:  Sleep       Date:  2003-11-01       Impact factor: 5.849

8.  The occurrence of sleep-disordered breathing among middle-aged adults.

Authors:  T Young; M Palta; J Dempsey; J Skatrud; S Weber; S Badr
Journal:  N Engl J Med       Date:  1993-04-29       Impact factor: 91.245

9.  Full polysomnography in the home.

Authors:  J M Fry; M A DiPhillipo; K Curran; R Goldberg; A S Baran
Journal:  Sleep       Date:  1998-09-15       Impact factor: 5.849

10.  Assessment of accuracy and analysis time of a novel device to monitor sleep and breathing in the home.

Authors:  D P White; T J Gibb; J M Wall; P R Westbrook
Journal:  Sleep       Date:  1995-02       Impact factor: 5.849

View more
  1 in total

Review 1.  Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation.

Authors:  Nancy A Collop; Sharon L Tracy; Vishesh Kapur; Reena Mehra; David Kuhlmann; Sam A Fleishman; Joseph M Ojile
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.