Sonicated X-ray contrast agents for quantitative myocardial contrast echocardiography--a critical approach.

I V Mayer1, M P Lazarov, U Utzinger, A U Freiburghaus, O M Hess.   

Abstract

Contrast echocardiography with sonicated radiographic contrast agents has been used for the qualitative and quantitative determination of myocardial blood flow. One major problem has been the size of the microbubbles since only bubbles smaller than 8 microns are expected to pass the capillary bed and larger bubbles may obstruct the capillaries and, thus, alter myocardial blood flow. These techniques have been used for several years, but their reliability has not yet been assessed accurately. Five different methods for the production of sonicated radiographic contrast agents (methods 1-3 from the literature, and 4 and 5 from our laboratory; M1-5) were evaluated for their use in quantitative contrast echocardiography. The sonication of non-ionic X-ray contrast media was performed with a standard titanium probe (20 kHz) for methods 1-4, with variation in the sonication time and the number of sonication jets used for each method. In M5, we used bubbles that were produced by the insufflation of oxygen in the X-ray contrast agent; large (> 8 microns) bubbles were destroyed by sonication at 380 kHz (resonance method). Mean bubble size was determined by computerized videomicroscopy. The effect of bubble size on the backscatter of the ultrasonic signal was calculated for each method. Mean bubble size (+/- 1 SD) ranged between 11.5 +/- 4 microns and 16.1 +/- 14 microns for M1-M5. The best values, i.e., the smallest bubbles, were found with M4 (prepressurized contrast medium). Assuming capillary passage for bubbles smaller than 8 microns, only 14%-48% of the bubbles were smaller than 8 microns (M1-M5). The best results with regard to bubble size (< or = 8 microns) were observed with M5 (48% < or = 8 microns). In regard to the influence of bubble size on the backscatter of the ultrasonic signal, 56%-98.5% of the signal was produced by bubbles larger than 15 microns (M1-5) but the best results were obtained with M4. It is concluded that capillary-passage of sonicated microbubbles (< or = 8 microns) can be expected in only 14%-48% of the bubbles for the five different sonication techniques. More than 50% of all microbubbles produced by these techniques are larger than the expected 8 microns. These large bubbles are responsible for the backscatter of the ultrasonic signal in the vast majority of cases. Thus, the sonication of radiographic contrast agents appears to be inappropriate for the production of uniformly small microbubbles and, thus, this method is not suitable for quantitative measurements of coronary blood flow.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7782270     DOI: 10.1007/bf01744500

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  36 in total

1.  Assessment of regional myocardial perfusion by contrast echocardiography. II. Detection of changes in transmural and subendocardial perfusion during dipyridamole-induced hyperemia in a model of critical coronary stenosis.

Authors:  J Cheirif; W A Zoghbi; R Bolli; P G O'Neill; B D Hoyt; M A Quinones
Journal:  J Am Coll Cardiol       Date:  1989-11-15       Impact factor: 24.094

2.  Albunex: a safe and effective commercially produced agent for myocardial contrast echocardiography.

Authors:  M W Keller; W Glasheen; S Kaul
Journal:  J Am Soc Echocardiogr       Date:  1989 Jan-Feb       Impact factor: 5.251

3.  Absorption and scatter of encapsulated gas filled microspheres: theoretical considerations and some measurements.

Authors:  N de Jong; L Hoff; T Skotland; N Bom
Journal:  Ultrasonics       Date:  1992-03       Impact factor: 2.890

4.  Reproducibility of quantitative myocardial contrast echocardiography.

Authors:  J R Shapiro; S A Reisner; A F Amico; P F Kelly; R S Meltzer
Journal:  J Am Coll Cardiol       Date:  1990-03-01       Impact factor: 24.094

5.  Contrast echocardiography during coronary arteriography in humans: perfusion and anatomic studies.

Authors:  S B Feinstein; R M Lang; C Dick; A Neumann; J Al-Sadir; K G Chua; J Carroll; T Feldman; K M Borow
Journal:  J Am Coll Cardiol       Date:  1988-01       Impact factor: 24.094

6.  Myocardial contrast two-dimensional echocardiography: a complement to coronary angiography.

Authors:  S Meerbaum
Journal:  J Am Coll Cardiol       Date:  1988-10       Impact factor: 24.094

7.  Myocardial washout of sonicated iopamidol does not reflect the transmural distribution of coronary blood flow.

Authors:  D Rovai; G Ghelardini; M Lombardi; M G Trivella; E Nevola; L Taddei; E M Ferdeghini; A Distante; A L'Abbate
Journal:  Eur Heart J       Date:  1993-08       Impact factor: 29.983

8.  [Contrast echocardiography in the evaluation of myocardial flow reserve].

Authors:  V Klauss; O Meissner; J Metz; K Theisen; H Mudra
Journal:  Z Kardiol       Date:  1993-12

9.  Two-dimensional contrast echocardiography. II. Transpulmonary studies.

Authors:  F J Ten Cate; S Feinstein; W Zwehl; S Meerbaum; M Fishbein; P M Shah; E Corday
Journal:  J Am Coll Cardiol       Date:  1984-01       Impact factor: 24.094

10.  [Myocardial contrast echocardiography for the follow-up after percutaneous transluminal coronary angioplasty].

Authors:  H Mudra; V Klauss; J Metz; O Meissner; W Zwehl; K Theisen
Journal:  Dtsch Med Wochenschr       Date:  1992-09-04       Impact factor: 0.628

View more
  1 in total

Review 1.  [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].

Authors:  M Haude; G Caspari; D Baumgart; P Spiller; G Heusch; R Erbel
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.