Literature DB >> 8404937

Myocardial washout of sonicated iopamidol does not reflect the transmural distribution of coronary blood flow.

D Rovai1, G Ghelardini, M Lombardi, M G Trivella, E Nevola, L Taddei, E M Ferdeghini, A Distante, A L'Abbate.   

Abstract

It has been shown in previous studies that myocardial contrast echocardiography provides quantitative information on coronary blood flow. However, the ability of contrast echo to assess the transmural (endo/epicardial) distribution of blood flow is still debated. To test this hypothesis, the left circumflex coronary arteries of six anaesthetized open-chested dogs were cannulated and perfused with blood from the femoral artery. At different rates of coronary blood flow, during adenosine-induced coronary vasodilation, sonicated iopamidol and radionuclide labelled microspheres were injected into the coronary cannula, immediately proximal to a mixing chamber. Two-D echo images were digitized and myocardial time-intensity curves were obtained for the endocardial, mid- and epicardial layers. A good correlation existed between contrast washout of the entire ventricular wall and coronary flow (r = 0.85). However, the washout rate from the endo-, mid- and epicardial layers showed weak correlations with corresponding regional blood flows measured by microspheres (r = 0.56, 0.71 and 0.58, respectively). No significant relationship was found between the endo/epicardial washout ratio and the corresponding flow ratio by microspheres. Thus, measurement of the transmural distribution of coronary blood flow by myocardial contrast echocardiography remains an elusive goal.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8404937     DOI: 10.1093/eurheartj/14.8.1072

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  2 in total

Review 1.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

2.  Sonicated X-ray contrast agents for quantitative myocardial contrast echocardiography--a critical approach.

Authors:  I V Mayer; M P Lazarov; U Utzinger; A U Freiburghaus; O M Hess
Journal:  Heart Vessels       Date:  1995       Impact factor: 2.037

  2 in total