Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation?

C H Won1, T C Hearn, M Tile.   

Abstract

Adult human cadaver pelves were tested to determine micromotion at the prosthesis-bone interface in cementless hemispherical acetabular components during simulated single-limb stance. The micromotion of non-press-fit components with screw fixation in response to cyclic loads to a maximum of 1500N was compressive (interface closing) at the superior iliac rim and distractive (interface opening) at the inferior ischial rim; that of press-fit components was compressive all around the acetabular rim regardless of screw fixation. Adding screws to the component decreased the micromotion at the site of the screw, but sometimes increased it at the opposite side. Two dome screws with the press-fit component decreased the micromotion at the superior iliac rim but at the inferior ischial rim there was either no change or increased movement. A press-fit cup shows less micromotion than a non-press-fit cup with screw fixation. The addition of screws to a press-fit cup does not necessarily increase the initial stability.

Entities:  

Mesh:

Year:  1995        PMID: 7744942

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  15 in total

1.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

2.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

3.  [Does osteoporosis lead to reduction the primary stability of cementless hip cups?].

Authors:  C von Schulze-Pellengahr; A Bürkner; T Lichtinger; W Teske; A Fottner; B Wegener; T Vogel
Journal:  Orthopade       Date:  2011-07       Impact factor: 1.087

4.  Validation of FE micromotions and strains around a press-fit cup: introducing a new micromotion measuring technique.

Authors:  S G Clarke; A T M Phillips; A M J Bull
Journal:  Ann Biomed Eng       Date:  2012-02-16       Impact factor: 3.934

5.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

6.  Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty.

Authors:  C Zilkens; S Djalali; B Bittersohl; T Kälicke; C N Kraft; R Krauspe; Marcus Jäger
Journal:  Eur J Med Res       Date:  2011-03-28       Impact factor: 2.175

7.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

8.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

9.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

10.  No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome.

Authors:  Michiel J M Minten; Petra J C Heesterbeek; Maarten Spruit
Journal:  Acta Orthop       Date:  2016-06-14       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.