Literature DB >> 7743741

In-vivo investigation of material quality of bone tissue by measuring apparent phalangeal ultrasound transmission velocity.

P Kann, U Schulz, D Klaus, B Piepkorn, J Beyer.   

Abstract

The square of ultrasound transmission velocity in a material is related to the modulus of elasticity, which is known to be an indicator of stability in bone. The aim of our study was to use ultrasound transmission velocity to obtain information about the material properties of bone tissue, keeping other factors possibly influencing ultrasound transmission as constant as possible. Apparent phalangeal ultrasound transmission velocity (APU) measured in 54 isolated, fresh pig phalanges was shown to be independent of bone mineral density (BMD) measured by SPA. Fastest sound transmission led exclusively through cortical bone so that intertrabecular connectivity in spongious bone could not influence the result. In humans APU was measured in the mediolateral direction at the midphalanx of the middle finger. In 53 healthy subjects (15-81 years old; 27 women, 26 men), there was a decrease of APU with age (r = -0.30, p < 0.05). Further, when comparing the results of both hands intraindividually almost identical values indicated constant intraindividual architecture of bone at this location. There was no evidence for a relation of APU to physical load comparing dominant and nondominant hand and relating the results to subjectively estimated physical load. In a second group of 43 perimenopausal women (47-60 years old), APU, which again decreased with age (r = -0.33, p < 0.05), was found not to be correlated to BMD measured by SPA at the distal forearm (cortical bone).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7743741     DOI: 10.1007/BF02208081

Source DB:  PubMed          Journal:  Clin Rheumatol        ISSN: 0770-3198            Impact factor:   2.980


  24 in total

1.  Noninvasive assessment of ulnar bending stiffness in women.

Authors:  F McCabe; L J Zhou; C R Steele; R Marcus
Journal:  J Bone Miner Res       Date:  1991-01       Impact factor: 6.741

2.  In vitro comparison of quantitative computed tomography and broadband ultrasonic attenuation of trabecular bone.

Authors:  M L McKelvie; J Fordham; C Clifford; S B Palmer
Journal:  Bone       Date:  1989       Impact factor: 4.398

3.  Ultrasonics and selected physical properties of bone.

Authors:  W Abendschein; G W Hyatt
Journal:  Clin Orthop Relat Res       Date:  1970 Mar-Apr       Impact factor: 4.176

4.  Comparison of broadband ultrasonic attenuation of the os calcis and quantitative computed tomography of the distal radius.

Authors:  C J Hosie; D A Smith; A D Deacon; C M Langton
Journal:  Clin Phys Physiol Meas       Date:  1987-11

5.  Effect of fluoride treatment on the fracture rate in postmenopausal women with osteoporosis.

Authors:  B L Riggs; S F Hodgson; W M O'Fallon; E Y Chao; H W Wahner; J M Muhs; S L Cedel; L J Melton
Journal:  N Engl J Med       Date:  1990-03-22       Impact factor: 91.245

6.  Architecture in cortical bone and ultrasound transmission velocity.

Authors:  P Kann; U Schulz; M Nink; A Pfützner; J Schrezenmeir; J Beyer
Journal:  Clin Rheumatol       Date:  1993-09       Impact factor: 2.980

7.  Factors affecting the determination of the physical properties of femoral cortical bone.

Authors:  E D Sedlin; C Hirsch
Journal:  Acta Orthop Scand       Date:  1966

8.  Regional bone mineral in healthy and osteoporotic women: a cross-sectional study.

Authors:  A Gotfredsen; L Nilas; J Pødenphant; A Hadberg; C Christiansen
Journal:  Scand J Clin Lab Invest       Date:  1989-12       Impact factor: 1.713

9.  Ultrasound as a tool for assessment of bone quality in the horse.

Authors:  L B Jeffcott; R N McCartney
Journal:  Vet Rec       Date:  1985-03-30       Impact factor: 2.695

10.  Osteoporotic bone fragility. Detection by ultrasound transmission velocity.

Authors:  R P Heaney; L V Avioli; C H Chesnut; J Lappe; R R Recker; G H Brandenburger
Journal:  JAMA       Date:  1989-05-26       Impact factor: 56.272

View more
  1 in total

1.  Ultrasound transmission velocity of the irradiated jaw bone in vivo.

Authors:  B Al-Nawas; K A Grötz; P Kann
Journal:  Clin Oral Investig       Date:  2001-12       Impact factor: 3.573

  1 in total