Literature DB >> 2048432

Noninvasive assessment of ulnar bending stiffness in women.

F McCabe1, L J Zhou, C R Steele, R Marcus.   

Abstract

The load-carrying capacity of cortical bone is closely related to its geometry and to its fundamental material properties, including mineral content (BMC). Together these determine the bending stiffness EI, where I is the cross-sectional moment of inertia and E is Young's modulus of elasticity. To assess the relationship of BMC and bone width (BW) to EI in healthy women, we used mechanical response tissue analysis (MRTA), a noninvasive method that involves analysis of tissue responses to ulnar vibration. A total of 48 healthy women were enrolled into an older (64 +/- 1y, n = 25) and a younger (25 +/- 0.6y, n = 23) group. BMC and BW of the dominant ulna were measured by single-photon absorptiometry (SPA). EI was determined by MRTA. BMC (0.75 +/- 0.02 versus 0.63 +/- 0.02 g/cm), BMC/BW (0.75 +/- 0.02 versus 0.63 +/- 0.02 g/cm2), and EI (27.7 +/- 1.3 versus 21.3 +/- 1.1 N.m2) were significantly greater (p less than 0.005) in the young subjects. BW did not change with age (1.00 +/- 0.01 versus 1.01 +/- 0.01 cm). In young women, simple correlations of BMC and BW with EI were both significant. By multiple regression analysis only BW independently predicted EI (EI = -0.35 + 39.1 x BMC, R2 = 0.52). In older women BMC and BW correlated with EI, but in multiple regression only BMC was significant (EI = -34.5 + 62.1 x BW; R2 = 0.45). When this analysis of older women included only those whose BMC values were within 2 SD of the young mean, BMC remained the only significant predictor of EI.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 2048432     DOI: 10.1002/jbmr.5650060110

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  12 in total

Review 1.  Infrared assessment of bone quality: a review.

Authors:  Eleftherios P Paschalis; Richard Mendelsohn; Adele L Boskey
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Ulnar and tibial bending stiffness as an index of bone strength in synchronized swimmers and gymnasts.

Authors:  Michael T C Liang; Sara B Arnaud; Charles R Steele; Patrick Hatch; Alexjandro Moreno
Journal:  Eur J Appl Physiol       Date:  2005-04-28       Impact factor: 3.078

3.  Fourier transform infrared analysis and bone.

Authors:  E P Paschalis
Journal:  Osteoporos Int       Date:  2009-06       Impact factor: 4.507

4.  Response to Loucks et al.'s Comment on "Clinical Evaluation of Bone Strength and Fracture Risk".

Authors:  X Sherry Liu; Chantal M J de Bakker; Wei-Ju Tseng; Yihan Li; Hongbo Zhao
Journal:  Curr Osteoporos Rep       Date:  2017-08       Impact factor: 5.096

5.  Clinical determination of bone quality: is ultrasound an answer?

Authors:  G H Brandenburger
Journal:  Calcif Tissue Int       Date:  1993       Impact factor: 4.333

6.  Age-dependence of bone material quality shown by the measurement of frequency of resonance in the ulna.

Authors:  P Kann; S Graeben; J Beyer
Journal:  Calcif Tissue Int       Date:  1994-02       Impact factor: 4.333

7.  Morphology, localization and accumulation of in vivo microdamage in human cortical bone.

Authors:  Tamim Diab; Deepak Vashishth
Journal:  Bone       Date:  2006-11-13       Impact factor: 4.398

8.  Bone quality determined by Fourier transform infrared imaging analysis in mild primary hyperparathyroidism.

Authors:  Ruth Zoehrer; David W Dempster; John P Bilezikian; Hua Zhou; Shonni J Silverberg; Elizabeth Shane; Paul Roschger; Eleftherios P Paschalis; Klaus Klaushofer
Journal:  J Clin Endocrinol Metab       Date:  2008-07-01       Impact factor: 5.958

Review 9.  Vibrational spectroscopic imaging for the evaluation of matrix and mineral chemistry.

Authors:  S Gamsjaeger; R Mendelsohn; A L Boskey; S Gourion-Arsiquaud; K Klaushofer; E P Paschalis
Journal:  Curr Osteoporos Rep       Date:  2014-12       Impact factor: 5.096

10.  In-vivo investigation of material quality of bone tissue by measuring apparent phalangeal ultrasound transmission velocity.

Authors:  P Kann; U Schulz; D Klaus; B Piepkorn; J Beyer
Journal:  Clin Rheumatol       Date:  1995-01       Impact factor: 2.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.