Literature DB >> 7734232

Mechanical and histological evaluation of hydroxyapatite-coated, titanium-coated and grit-blasted surfaces under weight-bearing conditions.

A Dávid1, J Eitenmüller, G Muhr, A Pommer, H F Bär, P A Ostermann, T A Schildhauer.   

Abstract

Cylindric titanium rods with different surfaces were axially implanted into the femora of sheep. The three surfaces were grit-blasted titanium, plasma-sprayed titanium and plasma-sprayed hydroxyapatite (HA). After 2 months, a 2-cm segment of the femoral shaft was completely resected to load the implant, and the animals were allowed full weight-bearing for 9 months. Biomechanical and histological evaluation of the implants was undertaken 2 months after implantation and 9 months after the segmental resection. The mechanical testings of well-fixed implants were performed 9 months after segmental resection. Loosening of 45% of the titanium-coated implants was observed in the first 3 weeks, but thereafter, no further loosening occurred. The HA-coated implants remained entirely fixed for 3 weeks, but thereafter, a progressively increasing incidence of loosening up to 55% after 9 months of loading was detected as subsidence on X-radiographs. The maximum push-out strength of the titanium-coated implants was 4.9 MPa compared with 2.3 MPa for HA-coated ones. No significant mechanical interlock between the grit-blasted surface and bone was observed. The HA coating was found to be delaminated in all unstable implants, whereas the titanium coating remained completely intact. Morphometric analyses of well-fixed rods showed complete bony ingrowth onto the HA surface, whereas the contact area between the bone and the two titanium surfaces was less than 40%. Concerning clinical significance bony ingrowth with long-term mechanical interlock between the implant surface and the bone cannot be achieved by grit-blasting or HA-coating.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7734232     DOI: 10.1007/bf00422838

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  34 in total

1.  Bonding of bone to apatite-coated implants.

Authors:  R G Geesink; K de Groot; C P Klein
Journal:  J Bone Joint Surg Br       Date:  1988-01

2.  Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates.

Authors:  R G Geesink; K de Groot; C P Klein
Journal:  Clin Orthop Relat Res       Date:  1987-12       Impact factor: 4.176

3.  Optimum pore size for bone cement fixation.

Authors:  S D Cook; N Thongpreda; R C Anderson; K A Thomas; R J Haddad; C D Griffin
Journal:  Clin Orthop Relat Res       Date:  1987-10       Impact factor: 4.176

4.  An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous, and cemented femoral components.

Authors:  T W Bauer; S K Taylor; M Jiang; S V Medendorp
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

5.  A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.

Authors:  T M Turner; D R Sumner; R M Urban; D P Rivero; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1986-12       Impact factor: 5.284

6.  Hip arthroplasty with a Moore prosthesis with porous coating. A five-year study.

Authors:  C A Engh
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

7.  The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study.

Authors:  G Lord; P Bancel
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

8.  Complications with hydroxyapatite particulate separation in total hip arthroplasty.

Authors:  R D Bloebaum; D Beeks; L D Dorr; C G Savory; J A DuPont; A A Hofmann
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

9.  Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy.

Authors:  T W Bauer; R C Geesink; R Zimmerman; J T McMahon
Journal:  J Bone Joint Surg Am       Date:  1991-12       Impact factor: 5.284

10.  Effect of stem modulus in a total hip arthroplasty model.

Authors:  G L Maistrelli; V Fornasier; A Binnington; K McKenzie; V Sessa; I Harrington
Journal:  J Bone Joint Surg Br       Date:  1991-01
View more
  7 in total

1.  Long-term follow-up (11 years plus) results of JRI (Furlong) total hip arthroplasty in young patients: cause for concern regarding acetabular cup?

Authors:  D K Sharma; Stuart Brooks
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

2.  Osteoblast response and calcium deposition on phospholipid modified surfaces.

Authors:  Neera Satsangi; Arpan Satsangi; Renee Glover; Joo L Ong; Rajiv K Satsangi
Journal:  J Mater Sci Mater Med       Date:  2004-06       Impact factor: 3.896

3.  Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces.

Authors:  Regina F MacBarb; Derek P Lindsey; Chelsea S Bahney; Shane A Woods; Mark L Wolfe; Scott A Yerby
Journal:  Int J Spine Surg       Date:  2017-06-01

4.  Bone tissue response to porous and functionalized titanium and silica based coatings.

Authors:  Amol Chaudhari; Annabel Braem; Jozef Vleugels; Johan A Martens; Ignace Naert; Marcio Vivan Cardoso; Joke Duyck
Journal:  PLoS One       Date:  2011-09-15       Impact factor: 3.240

5.  Changes in the surface of bone and acid-etched and sandblasted implants following implantation and removal.

Authors:  Cennet Neslihan Eroglu; Abdullah Seckin Ertugrul; Murat Eskitascioglu; Gurcan Eskitascioglu
Journal:  Eur J Dent       Date:  2016 Jan-Mar

6.  Modified Titanium Surface-Mediated Effects on Human Bone Marrow Stromal Cell Response.

Authors:  Amol Chaudhari; Joke Duyck; Annabel Braem; Jozef Vleugels; Hervé Petite; Delphine Logeart-Avramoglou; Ignace Naert; Johan A Martens; Katleen Vandamme
Journal:  Materials (Basel)       Date:  2013-11-28       Impact factor: 3.623

7.  Combining 3D human in vitro methods for a 3Rs evaluation of novel titanium surfaces in orthopaedic applications.

Authors:  G Stevenson; S Rehman; E Draper; E Hernández-Nava; J Hunt; J W Haycock
Journal:  Biotechnol Bioeng       Date:  2016-01-21       Impact factor: 4.530

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.