Literature DB >> 7724752

Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement.

J P Heiken1, J A Brink, B L McClennan, S S Sagel, T M Crowe, M V Gaines.   

Abstract

PURPOSE: To develop an individualized approach to the intravenous administration of contrast material for hepatic computed tomography (CT).
MATERIALS AND METHODS: Two hundred patients were randomized into eight protocols. Each group received different volumes and concentrations of contrast material. For each protocol, maximum hepatic enhancement (MHE) was calculated, with an adjustment for iodine dose and patient weight. The contrast enhancement index (CEI) and optimum scanning interval were calculated for hepatic enhancement thresholds of 10-60 HU.
RESULTS: The MHE calculated as a function of patient weight was 96 HU +/- 19 per gram of iodine per kilogram of body weight. CEIs obtained with a contrast material concentration of 240 mg of iodine per milliliter were inferior to those obtained with a concentration of 320 or 350 mg I/mL. At low enhancement thresholds, the volume of contrast material had a more important effect than the concentration on CEI and optimum scanning interval; at high thresholds, concentration had a more important effect.
CONCLUSION: For a patient of known weight, one can calculate the iodine dose needed to provide a desired level of hepatic enhancement. Use of a contrast material with a concentration of 240 mg L/mL is not recommended for dynamic incremental hepatic CT, except in small patients (eg, those weighing less than 73 kg).

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7724752     DOI: 10.1148/radiology.195.2.7724752

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  49 in total

1.  Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.

Authors:  Hiromasa Suzuki; Hidekazu Oshima; Norio Shiraki; Chisa Ikeya; Yuta Shibamoto
Journal:  Eur Radiol       Date:  2004-08-12       Impact factor: 5.315

2.  Standardisation of liver MDCT by tracking liver parenchyma enhancement to trigger imaging.

Authors:  H Brodoefel; A Tognolini; G A Zamboni; S Gourtsoyianni; C D Claussen; V Raptopoulos
Journal:  Eur Radiol       Date:  2011-11-05       Impact factor: 5.315

3.  Preliminary experience with abdominal dual-energy CT (DECT): true versus virtual nonenhanced images of the liver.

Authors:  C N De Cecco; V Buffa; S Fedeli; A Vallone; R Ruopoli; M Luzietti; V Miele; M Rengo; M Maurizi Enrici; P Fina; A Laghi; V David
Journal:  Radiol Med       Date:  2010-09-17       Impact factor: 3.469

4.  Image quality in CT perfusion imaging of the brain. The role of iodine concentration.

Authors:  Matthias König; Eva Bültmann; Lucas Bode-Schnurbus; Dirk Koenen; Eckhart Mielke; Lothar Heuser
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

5.  Enhancement of the liver on dynamic MDCT: investigation among three groups consisting of noncirrhotic patients and cirrhotic patients with and without a large portosystemic shunt.

Authors:  Kouichirou Naruo; Mitsuhiro Tozaki; Yasushi Fukuda; Kunihiko Fukuda
Journal:  Radiat Med       Date:  2007-04-27

6.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

7.  Correlation of abdominal fat ratio with hepatic CT enhancement.

Authors:  Qing Zhang; Mu-Jie Guo; Yu-Fen Wu
Journal:  Exp Ther Med       Date:  2015-05-06       Impact factor: 2.447

8.  Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT.

Authors:  Florian F Behrendt; Hubertus Pietsch; Gregor Jost; Martin A Sieber; Sebastian Keil; Cedric Plumhans; Peter Seidensticker; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2010-02-24       Impact factor: 5.315

9.  Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT.

Authors:  Kazuo Awai; Shinichi Hori
Journal:  Eur Radiol       Date:  2003-05-08       Impact factor: 5.315

10.  Pancreatic adenocarcinoma: analysis of the effect of various concentrations of contrast material.

Authors:  Yoshihiko Fukukura; Hiroyuki Hamada; Takuro Kamiyama; Tomohide Yoneyama; Koji Takumi; Masayuki Nakajo
Journal:  Radiat Med       Date:  2008-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.