Literature DB >> 7714649

A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator.

T Miclau1, A Remiger, S Tepic, R Lindsey, T McIff.   

Abstract

Cortical bone porosis associated with the dynamic compression plate (DCP) prompted the development of the limited-contact dynamic compression plate (LC-DCP) and the point-contact fixator (PC-Fix) to increase bone vascularity. However, the comparative fixation characteristics of the three designs are unknown. Transverse fractures were physiologically created in paired cadaveric sheep tibiae, which were plated before torsion testing and four-point bending to failure. The tibiae were grouped randomly and compared as follows: DCP versus LC-DCP, DCP versus PC-Fix, and LC-DCP versus PC-Fix. Mean torque to failure demonstrated no significant difference between the three plates (p < 0.33). Mean bending stiffness, gap opening, and moment to failure also demonstrated no significant difference between the three designs with p < 0.29, < 0.13, and < 0.16, respectively. The LC-DCP and PC-Fix have torsion and bending properties comparable with the DCP in the fixation of simple transverse diaphyseal fractures.

Entities:  

Mesh:

Year:  1995        PMID: 7714649     DOI: 10.1097/00005131-199502000-00003

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  4 in total

Review 1.  Clinical application of locked plating system in children. An orthopaedic view.

Authors:  Juan Pretell-Mazzini; Jose Alberto Zafra-Jimenez; Juan Rodriguez Martin
Journal:  Int Orthop       Date:  2010-02-17       Impact factor: 3.075

2.  Morphological evaluation of eccentric sets guide-plates of dcp-l 4.5 mm.

Authors:  José Humberto de Souza Borges; Antonio Lisboa da Silva Filho; Francisco Pereira Neto; Walter Rodrigo Daher; Alessandro Queiroz de Mesquita; Anderson Freitas
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

3.  Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength.

Authors:  Michael Bottlang; Josef Doornink; Daniel C Fitzpatrick; Steven M Madey
Journal:  J Bone Joint Surg Am       Date:  2009-08       Impact factor: 5.284

4.  A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture.

Authors:  Bowei Liang; Zhenqi Ding; Junguo Shen; Wenliang Zhai; Liangqi Kang; Liang Zhou; Mo Sha; Dongzhu Liang
Journal:  Int Orthop       Date:  2012-05-13       Impact factor: 3.075

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.