Literature DB >> 7714601

Effects of coregistration of MR to CT images on MR stereotactic accuracy.

D S Cohen1, J H Lustgarten, E Miller, A G Khandji, R R Goodman.   

Abstract

Coregistration of different modality imaging serves to increase the ease and accuracy of stereotactic procedures. In many cases, magnetic resonance (MR) stereotaxis is supplanting computerized tomography (CT). The advantages of increased anatomical detail and multiplanar imaging afforded by MR, however, are offset by its potential inaccuracy as well as the more cumbersome and less available nature of its hardware. A system has been developed by one of the authors by which MR imaging can be performed separately without a stereotactic fiducial headring. Then, immediately prior to surgery, a stereotactic CT scan is obtained and software is used to coregister CT and MR images anatomically by matching cranial landmarks in the two scans. The authors examined this system in six patients as well as with the use of a lucite phantom. After initially coregistering CT and MR images, six separate anatomical (for the patients) and eight artificial (for the phantom) targets were compared. With coregistration, in comparison to CT fiducial scans, errors in each axis are less than or equal to 1 mm using the Cosman-Roberts-Wells system. In fact, the coregistered images are more accurate than MR fiducial images, in the anteroposterior (p = 0.001), lateral (p < 0.05), and vertical (p < 0.03) planes. Three-dimensional error was significantly less in the coregistered scans than the MR fiducial images (p < 0.005). The coregistration procedure therefore not only increases the case of MR stereotaxis but also increases its accuracy.

Entities:  

Mesh:

Year:  1995        PMID: 7714601     DOI: 10.3171/jns.1995.82.5.0772

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  9 in total

1.  Focal enhancement of cranial nerve V after radiosurgery with the Leksell gamma knife: experience in 15 patients with medically refractory trigeminal neuralgia.

Authors:  R A Alberico; R A Fenstermaker; J Lobel
Journal:  AJNR Am J Neuroradiol       Date:  2001 Nov-Dec       Impact factor: 3.825

2.  Technical note: the design of a stereotactic frame for direct MRI-anatomical correlation of the brachial plexus.

Authors:  Tom Van Hoof; Cyriel Mabilde; Luc Leybaert; Koenraad Verstraete; Katharina D'Herde
Journal:  Surg Radiol Anat       Date:  2005-10-25       Impact factor: 1.246

3.  Image coregistration: quantitative processing framework for the assessment of brain lesions.

Authors:  Hannu Huhdanpaa; Darryl H Hwang; Gregory G Gasparian; Michael T Booker; Yong Cen; Alexander Lerner; Orest B Boyko; John L Go; Paul E Kim; Anandh Rajamohan; Meng Law; Mark S Shiroishi
Journal:  J Digit Imaging       Date:  2014-06       Impact factor: 4.056

4.  Investigating the function of deep cortical and subcortical structures using stereotactic electroencephalography: lessons from the anterior cingulate cortex.

Authors:  Robert A McGovern; Tarini Ratneswaren; Elliot H Smith; Jennifer F Russo; Amy C Jongeling; Lisa M Bateman; Catherine A Schevon; Neil A Feldstein; Guy M McKhann; Sameer Sheth
Journal:  J Vis Exp       Date:  2015-04-15       Impact factor: 1.355

5.  Comparison of registration accuracy of skin- and bone-implanted fiducials for frameless stereotaxis of the brain: a prospective study.

Authors:  Mario Ammirati; Jeffrey D Gross; Giuseppe Ammirati; Sharon Dugan
Journal:  Skull Base       Date:  2002-08

6.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

7.  An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system.

Authors:  C Yu; Z Petrovich; M L Apuzzo; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

8.  Image fusion pitfalls for cranial radiosurgery.

Authors:  Benjamin P Jonker
Journal:  Surg Neurol Int       Date:  2013-04-17

9.  Gamma Knife® icon CBCT offers improved localization workflow for frame-based treatment.

Authors:  William N Duggar; Bart Morris; Ali Fatemi; Jemeria Bonds; Rui He; Madhava Kanakamedala; Roberto Rey-Dios; Srinivasan Vijayakumar; Claus Yang
Journal:  J Appl Clin Med Phys       Date:  2019-10-06       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.