Literature DB >> 16249823

Technical note: the design of a stereotactic frame for direct MRI-anatomical correlation of the brachial plexus.

Tom Van Hoof1, Cyriel Mabilde, Luc Leybaert, Koenraad Verstraete, Katharina D'Herde.   

Abstract

The purpose of this study was to identify optimal magnetic resonance imaging (MRI) conditions to visualize discrete alterations of brachial plexus components, as part of a biomechanical study of minor nerve compression syndromes. A method was developed allowing direct comparison between the MRI image and the subsequently obtained matching anatomic section of the same specimen. We designed a stereotactic frame to obtain the precise orientation of the MRI plane with reference to the specimen and adapted a vertical band saw for multiplanar sectioning of cadaveric specimens. Two cadaveric upper quadrants were examined by MRI (TR 450 ms, TE 13 ms, pixel matrix 512 x 512 and FOV 23-26 cm) and anatomical slices were produced. One specimen was sectioned axially, while the second specimen was sectioned in an oblique plane corresponding to the natural longitudinal axis of the upper part of the brachial plexus. MR images and the corresponding slices exhibited a strong correlation. This correlation was checked by using vitamin A pearls as landmarks. MR images revealed more detail after the correlating anatomical slices were analyzed. The present study shows that the method is suited for direct MRI-anatomic comparison of the brachial plexus and is also proposed for application to other topographical regions.

Entities:  

Mesh:

Year:  2005        PMID: 16249823     DOI: 10.1007/s00276-005-0049-9

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  30 in total

1.  Thoracic outlet: anatomic correlation with MR imaging.

Authors:  X Demondion; N Boutry; A Drizenko; C Paul; J P Francke; A Cotten
Journal:  AJR Am J Roentgenol       Date:  2000-08       Impact factor: 3.959

2.  Craniovertebral junction: normal anatomy with MR correlation.

Authors:  M E Schweitzer; J Hodler; V Cervilla; D Resnick
Journal:  AJR Am J Roentgenol       Date:  1992-05       Impact factor: 3.959

3.  Imaging of the peripheral nervous system: evaluation of peripheral neuropathy and plexopathy.

Authors:  K R Maravilla; B C Bowen
Journal:  AJNR Am J Neuroradiol       Date:  1998 Jun-Jul       Impact factor: 3.825

4.  A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system.

Authors:  L Walton; A Hampshire; D M Forster; A A Kemeny
Journal:  Neurosurgery       Date:  1996-01       Impact factor: 4.654

5.  MR imaging of the treated brachial plexus.

Authors:  R B Iyer; M J Fenstermacher; H I Libshitz
Journal:  AJR Am J Roentgenol       Date:  1996-07       Impact factor: 3.959

6.  Cross-sectional imaging anatomy of the anal sphincters.

Authors:  U M Peschers; J O DeLancey; H Fritsch; L E Quint; M R Prince
Journal:  Obstet Gynecol       Date:  1997-11       Impact factor: 7.661

7.  Brachial plexus: MR imaging with a dedicated phased array of surface coils.

Authors:  C E Hayes; J S Tsuruda; C M Mathis; K R Maravilla; M Kliot; A G Filler
Journal:  Radiology       Date:  1997-04       Impact factor: 11.105

8.  Anatomic correlation of cadaver cryomicrotomy with magnetic resonance imaging.

Authors:  R Lufkin; W Rauschning; L Seeger; L Bassett; W Hanafee
Journal:  Surg Radiol Anat       Date:  1987       Impact factor: 1.246

9.  Effect of geometrical distortion correction in MR on image registration accuracy.

Authors:  C R Maurer; G B Aboutanos; B M Dawant; S Gadamsetty; R A Margolin; R J Maciunas; J M Fitzpatrick
Journal:  J Comput Assist Tomogr       Date:  1996 Jul-Aug       Impact factor: 1.826

10.  Cerebral tuberous sclerosis: postmortem magnetic resonance imaging and pathologic anatomy.

Authors:  J R Nixon; G M Miller; H Okazaki; M R Gomez
Journal:  Mayo Clin Proc       Date:  1989-03       Impact factor: 7.616

View more
  1 in total

1.  Nerve loop around the axillary vessels by the roots of the median nerve a rare variation in a south Indian male cadaver: a case report.

Authors:  Kumar M R Bhat; Siddaraju Gowda; Bhagath Kumar Potu
Journal:  Cases J       Date:  2009-10-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.