Literature DB >> 7699047

Reliability of methods for hepatitis B virus DNA detection.

W G Quint1, R A Heijtink, J Schirm, W H Gerlich, H G Niesters.   

Abstract

A quality assurance program has been established by the European Group for Rapid Viral Diagnosis and the European Expert Group on Viral Hepatitis for monitoring nucleic acid detection methods for hepatitis B virus (HBV) DNA in serum samples. Thirty-nine laboratories participated in this quality program and generated 43 data sets. Of the participating laboratories, all but one used the PCR technique to detect HBV DNA. A coded panel was tested that was composed of seven undiluted HBV DNA-positive serum samples and five HBV DNA-negative donor serum samples. Furthermore, two dilution series, one from a positive patient and one from a full-length recombinant DNA, were included. Twenty-six data sets (60.5%) had faultless results with both dilution series. Twelve data sets (27.9%) recognized the undiluted serum samples, and 19 data sets (44.2%) had false-negative and/or false-positive results. Ten data sets (23.3%) performed well with the entire panel of samples. From these results, it can be concluded that in a large group of laboratories HBV detection by PCR shows specificity and sensitivity problems; therefore, PCR test interpretation should be done with great care.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7699047      PMCID: PMC227915          DOI: 10.1128/jcm.33.1.225-228.1995

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Rapid and simple method for purification of nucleic acids.

Authors:  R Boom; C J Sol; M M Salimans; C L Jansen; P M Wertheim-van Dillen; J van der Noordaa
Journal:  J Clin Microbiol       Date:  1990-03       Impact factor: 5.948

Review 2.  DNA diagnostics--molecular techniques and automation.

Authors:  U Landegren; R Kaiser; C T Caskey; L Hood
Journal:  Science       Date:  1988-10-14       Impact factor: 47.728

3.  Use of uracil DNA glycosylase to control carry-over contamination in polymerase chain reactions.

Authors:  M C Longo; M S Berninger; J L Hartley
Journal:  Gene       Date:  1990-09-01       Impact factor: 3.688

4.  A novel method employing UNG to avoid carry-over contamination in RNA-PCR.

Authors:  J S Epstein; I K Hewlett
Journal:  Nucleic Acids Res       Date:  1993-08-11       Impact factor: 16.971

5.  Sensitivity and specificity of PCR for detection of Mycobacterium tuberculosis: a blind comparison study among seven laboratories.

Authors:  G T Noordhoek; A H Kolk; G Bjune; D Catty; J W Dale; P E Fine; P Godfrey-Faussett; S N Cho; T Shinnick; S B Svenson
Journal:  J Clin Microbiol       Date:  1994-02       Impact factor: 5.948

6.  Dependence of polymerase chain reaction product inactivation protocols on amplicon length and sequence composition.

Authors:  M J Espy; T F Smith; D H Persing
Journal:  J Clin Microbiol       Date:  1993-09       Impact factor: 5.948

Review 7.  Polymerase chain reaction for the diagnosis of viral hepatitis B and C.

Authors:  C Bréchot
Journal:  Gut       Date:  1993       Impact factor: 23.059

8.  Reliability of polymerase chain reaction for detection of hepatitis C virus.

Authors:  H L Zaaijer; H T Cuypers; H W Reesink; I N Winkel; G Gerken; P N Lelie
Journal:  Lancet       Date:  1993-03-20       Impact factor: 79.321

  8 in total
  33 in total

1.  Multicenter quality assessment of PCR methods for detection of enteroviruses.

Authors:  P Muir; A Ras; P E Klapper; G M Cleator; K Korn; C Aepinus; A Fomsgaard; P Palmer; A Samuelsson; A Tenorio; B Weissbrich; A M van Loon
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

2.  A multicenter study evaluation of the digene hybrid capture II signal amplification technique for detection of hepatitis B virus DNA in serum samples and testing of EUROHEP standards.

Authors:  H G Niesters; M Krajden; L Cork; M de Medina; M Hill; E Fries; A D Osterhaus
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

3.  Reverse transcription-PCR analysis of bottled and natural mineral waters for the presence of noroviruses.

Authors:  Gilbert Thierry Lamothe; Thierry Putallaz; Han Joosten; Joey D Marugg
Journal:  Appl Environ Microbiol       Date:  2003-11       Impact factor: 4.792

Review 4.  False-positive results and contamination in nucleic acid amplification assays: suggestions for a prevent and destroy strategy.

Authors:  A Borst; A T A Box; A C Fluit
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-03-10       Impact factor: 3.267

5.  Follow-up on diagnostic proficiency of laboratories equipped to perform orthopoxvirus detection and quantification by PCR: the second international external quality assurance study.

Authors:  Matthias Niedrig; Hermann Meyer; Marcus Panning; Christian Drosten
Journal:  J Clin Microbiol       Date:  2006-04       Impact factor: 5.948

Review 6.  Molecular typing of enteroviruses: current status and future requirements. The European Union Concerted Action on Virus Meningitis and Encephalitis.

Authors:  P Muir; U Kämmerer; K Korn; M N Mulders; T Pöyry; B Weissbrich; R Kandolf; G M Cleator; A M van Loon
Journal:  Clin Microbiol Rev       Date:  1998-01       Impact factor: 26.132

7.  Comparative evaluation of semiautomated COBAS AMPLICOR hepatitis B virus (HBV) monitor test and manual microwell plate-based AMPLICOR HBV MONITOR test.

Authors:  I J Marin; M Poljak; K Seme; J Meglic-Volkar; M Maticic; G Lesnicar; V Brinovec
Journal:  J Clin Microbiol       Date:  2001-02       Impact factor: 5.948

8.  New enzyme immunoassay for detection of hepatitis B virus core antigen (HBcAg) and relation between levels of HBcAg and HBV DNA.

Authors:  Tatsuji Kimura; Akinori Rokuhara; Akihiro Matsumoto; Shintaro Yagi; Eiji Tanaka; Kendo Kiyosawa; Noboru Maki
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

9.  Quantitative assay of PCR-amplified hepatitis B virus DNA using a peroxidase-labelled DNA probe and enhanced chemiluminescence.

Authors:  A Erhardt; S Schaefer; N Athanassiou; M Kann; W H Gerlich
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

10.  Reliability of nucleic acid amplification methods for detection of Chlamydia trachomatis in urine: results of the first international collaborative quality control study among 96 laboratories.

Authors:  Roel P Verkooyen; Gerda T Noordhoek; Paul E Klapper; Jim Reid; Jurjen Schirm; Graham M Cleator; Margareta Ieven; Gunnar Hoddevik
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.