Literature DB >> 7695409

Comparison of implantation techniques using freestyle stentless porcine aortic valve.

N D Kon1, S Westaby, N Amarasena, R Pillai, A R Cordell.   

Abstract

Stentless porcine aortic valves demonstrate superior hemodynamic performance when compared with their stented counterparts. The technical considerations for implanting these valves can be demanding. The Medtronic Freestyle aortic root bioprosthesis resembles an allograft, has zero-pressure-fixed leaflets treated with an antimineralization agent, and can be implanted using a variety of techniques. In this study of that valve, total root replacement (TRR) was compared with a partial scallop aortic inclusion technique (PSI). Implications were performed in 75 patients (49 PSI and 26 TRR). There were no significant differences with respect to age, sex, or incidence of concomitant procedures. Mean aortic cross-clamp times were significantly less in the PSI group than in the TRR group (51.8 +/- 11.7 minutes versus 125.5 +/- 19.7 minutes; p = 0.0001). At discharge, mean systolic gradients seen on color-flow Doppler echocardiography were less in the TRR group than in the PSI group (6.17 +/- 3.66 versus 10.01 +/- 4.83 mm Hg; p = 0.014). Discharge echocardiography revealed trivial valve regurgitation in 8.3% of the TRR group and in 41.7% of the PSI group (p = 0.004). No patient experienced any significant valvular regurgitation on discharge echocardiography. We conclude that early experience with the Medtronic Freestyle aortic root bioprosthesis shows excellent short-term function regardless of implantation technique. Shorter cross-clamp times, comparable with those of stented valve procedures, occurred with PSI implantation. We anticipate that effects on long-term durability will be beneficial.

Entities:  

Mesh:

Year:  1995        PMID: 7695409     DOI: 10.1016/0003-4975(95)00066-t

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  11 in total

1.  Dynamic obstruction, an unusual complication after aortic valve replacement with a stentless porcine valve.

Authors:  R P van Roosmalen; L H Baur; J Braun; D E Atsma; M G Hazekamp; E E van der Wall; H A Huysmans
Journal:  Int J Card Imaging       Date:  1999-06

2.  Resolution of perivalvular hematoma of the Freestyle stentless aortic root bioprosthesis implanted with a subcoronary technique.

Authors:  Y Takami; H Ina
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-11

3.  Early experience of aortic valve replacement with the Freestyle stentless aortic bioprosthesis in elderly patients.

Authors:  S Ohtake; Y Sawa; T Sakaguchi; M Nishimura; H Satoh; G Matsumiya; Y Hayashi; H Matsuda
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-04

Review 4.  Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.

Authors:  Reza Tavakoli; Pichoy Danial; Ahmed Hamid Oudjana; Peiman Jamshidi; Max Gassmann; Pascal Leprince; Guillaume Lebreton
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-01-10

5.  Concomitant aortic arch and root replacement using a stentless xenograft for acute type A dissection.

Authors:  T Takahashi; Y Shimazaki; T Watanabe; T Minowa; T Uchida; S Toyama
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-06

6.  The use of a stentless porcine bioprosthesis to repair an ascending aortic aneurysm in combination with aortic valve regurgitation.

Authors:  B Akpinar; I Sanisoğlu; C Konuralp; H Akay; M Güden; B Sönmez
Journal:  Tex Heart Inst J       Date:  1999

7.  Mid term outcome and quality of life after aortic valve replacement in elderly people: mechanical versus stentless biological valves.

Authors:  I Florath; A Albert; U Rosendahl; T Alexander; I C Ennker; J Ennker
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

8.  Stentless aortic valves. Current aspects.

Authors:  J Ennker; A Albert; I C Ennker
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2012

Review 9.  Stentless aortic valve replacement: an update.

Authors:  Junjiro Kobayashi
Journal:  Vasc Health Risk Manag       Date:  2011-06-02

10.  Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle stentless bioprosthesis and its consequences: a follow-up study in 587 patients.

Authors:  Alexander Albert; Ines Florath; Ulrich Rosendahl; Wael Hassanein; Eberhard V Hodenberg; Stefan Bauer; Ina Ennker; Jürgen Ennker
Journal:  J Cardiothorac Surg       Date:  2007-10-05       Impact factor: 1.637

View more