Literature DB >> 11757342

Resolution of perivalvular hematoma of the Freestyle stentless aortic root bioprosthesis implanted with a subcoronary technique.

Y Takami1, H Ina.   

Abstract

The modified subcoronary technique is frequently used to implant the Freestyle aortic root bioprosthesis because of its ease. This technique is primarily associated with hematoma in the potential space between the prosthetic and native aortic walls. We report a case of resolution of perivalvular hematoma around the Freestyle valve 6 months after implantation in a patient with aneurysm of the noncoronary sinus of Valsalva. During follow-up, the patient underwent no significant changes in pressure gradient or degree of regurgitation. Although long-term results are not yet known, the subcoronary technique may be a feasible alternative for patients with aneurysms in the sinus of Valsalva to exclude it, unless the sinotubular junction and aortic annulus are intact.

Entities:  

Mesh:

Year:  2001        PMID: 11757342     DOI: 10.1007/bf02912479

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  7 in total

1.  Clinical and hemodynamic performance of the Freestyle aortic root bioprosthesis.

Authors:  P C Cartier; J G Dumesnil; J Métras; D Desaulniers; D P Doyle; M D Lemieux; G Raymond
Journal:  Ann Thorac Surg       Date:  1999-02       Impact factor: 4.330

2.  Early experience of aortic valve replacement with the Freestyle stentless aortic bioprosthesis in elderly patients.

Authors:  S Ohtake; Y Sawa; T Sakaguchi; M Nishimura; H Satoh; G Matsumiya; Y Hayashi; H Matsuda
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-04

Review 3.  Allograft aortic valve implantation: techniques for all types of aortic valve and root pathology.

Authors:  M F O'Brien; D C McGiffin; E G Stafford
Journal:  Ann Thorac Surg       Date:  1989-10       Impact factor: 4.330

4.  Aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis.

Authors:  N D Kon; A R Cordell; S M Adair; J E Dobbins; D W Kitzman
Journal:  Ann Thorac Surg       Date:  1999-06       Impact factor: 4.330

5.  Left ventricular remodelling and improvement in Freestyle stentless valve haemodynamics.

Authors:  X Y Jin; S Westaby; D G Gibson; R Pillai; D P Taggart
Journal:  Eur J Cardiothorac Surg       Date:  1997-07       Impact factor: 4.191

6.  Aortic valve replacement with allograft/autograft: subcoronary versus intraluminal cylinder or root.

Authors:  J E Rubay; D Raphael; T Sluysmans; J L Vanoverschelde; A Robert; J C Schoevaerdts; B Marchandise; R A Dion
Journal:  Ann Thorac Surg       Date:  1995-08       Impact factor: 4.330

7.  Comparison of implantation techniques using freestyle stentless porcine aortic valve.

Authors:  N D Kon; S Westaby; N Amarasena; R Pillai; A R Cordell
Journal:  Ann Thorac Surg       Date:  1995-04       Impact factor: 4.330

  7 in total