Literature DB >> 7689046

Influence of hemoglobin variants and derivatives on glycohemoglobin determinations, as investigated by 102 laboratories using 16 methods.

C W Weykamp1, T J Penders, F A Muskiet, W van der Slik.   

Abstract

Influences of hemoglobin (Hb) variants (HbSS, HbCC, beta-thalassemia, HbAE, HbAS, HbAC, hereditary persistent HbF) and Hb derivatives (carbamylated- and acetylated-Hbs, Schiff base, and those formed in stored blood) on results of glyco-Hb assays by 102 laboratories using 16 different methods were investigated. Affinity chromatography shows deviating results only with homozygous Hb S and C. Correct interpretation of results from patients with decreased erythrocyte half-lives requires previous knowledge on this condition. Measurements of HbA1c by HPLC and electrophoresis are obviously unsuitable for homozygous hemoglobinopathies; for heterozygous hemoglobinopathies and Hb synthesis variants, HbA1c should be expressed as percentage of HbA0 + HbA1c; abnormal Hbs are usually recognized; both carbamylated- and acetylated-Hbs interfere and Schiff base must be eliminated. Except for stored blood, all Hb variants and derivatives gave erroneous results with disposable ion-exchange columns. Dako's immunoassay is not affected by Hb derivatives; glycated Hb variants are not recognized as glyco-Hb and percentages are consequently too low. Glyco-Hb by the immunoassay of Bayer (performed by one laboratory) is not affected by Hb variants and derivatives.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 7689046

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  13 in total

Review 1.  A review of variant hemoglobins interfering with hemoglobin A1c measurement.

Authors:  Randie R Little; William L Roberts
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

2.  Effects of 49 Different Rare Hb Variants on HbA1c Measurement in Eight Methods.

Authors:  Randie R Little; Sonia L La'ulu; Steven E Hanson; Curt L Rohlfing; Robert L Schmidt
Journal:  J Diabetes Sci Technol       Date:  2015-02-17

3.  Lack of precision in HbA(1c) values on variant II in cases of hemoglobin Q India.

Authors:  P K Nigam; S Sharma; R Sareen; V Paul; A Lal
Journal:  Indian J Clin Biochem       Date:  2006-09

4.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

5.  Diagnostic Dilemma of HbA1c Detection in Presence of a Hemoglobinopathy: A Case Report.

Authors:  Vijay S Bhat; Kalyan Kumar Dewan; Patnam Rajagopalan Krishnaswamy
Journal:  Indian J Clin Biochem       Date:  2010-09-14

6.  HbA1c standardisation destination--global IFCC Standardisation. How, why, where and when--a tortuous pathway from kit manufacturers, via inter-laboratory lyophilized and whole blood comparisons to designated national comparison schemes.

Authors:  Ian Goodall
Journal:  Clin Biochem Rev       Date:  2005-02

7.  Emerging trends in optical sensing of glycemic markers for diabetes monitoring.

Authors:  Rishikesh Pandey; Narahara Chari Dingari; Nicolas Spegazzini; Ramachandra R Dasari; Gary L Horowitz; Ishan Barman
Journal:  Trends Analyt Chem       Date:  2015-01-01       Impact factor: 12.296

Review 8.  Glycemic control indicators in patients with neonatal diabetes mellitus.

Authors:  Shigeru Suzuki; Masafumi Koga
Journal:  World J Diabetes       Date:  2014-04-15

9.  Conditions associated with very low values of glycohaemoglobin measured by an HPLC method.

Authors:  J L Camargo; J L Gross
Journal:  J Clin Pathol       Date:  2004-04       Impact factor: 3.411

Review 10.  HbA1c: a review of analytical and clinical aspects.

Authors:  Cas Weykamp
Journal:  Ann Lab Med       Date:  2013-10-17       Impact factor: 3.464

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.