The proarrhythmic potential of implantable cardioverter-defibrillators.

S L Pinski1, G J Fahy.   

Abstract

The implantable cardioverter-defibrillator (ICD) is remarkably effective in preventing sudden cardiac death in high-risk patients, but it also has the capacity to provoke or worsen cardiac arrhythmias. Tachyarrhythmias or bradyarrhythmias may result from the delivery of antitachycardia or antibradycardia therapies by tiered-therapy defibrillators. This proarrhythmia, although rarely fatal, increases the morbidity associated with defibrillator therapy. Proarrhythmia is related as much to suboptimal programming as to technical limitations of the device. The proarrhythmic potential of ICD therapy can be minimized by tailoring the "electrical prescription" according to characteristics of the clinical arrhythmia and individual ICD idiosyncrasies.

Entities:  

Mesh:

Year:  1995        PMID: 7664453     DOI: 10.1161/01.cir.92.6.1651

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  24 in total

1.  Inappropriate implantable defibrillator discharge caused by a retained pacemaker lead fragment.

Authors:  L Lickfett; C Wolpert; W Jung; S Spehl; L Pizzulli; B Esmailzadeh; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1999-07       Impact factor: 1.900

2.  Prospective evaluation of the quality and long-term stability of atrial signals in non-thoracotomy defibrillation electrodes: comparison of four different endocardial electrograms.

Authors:  C Wolpert; W Jung; S Spehl; B Schumacher; H Omran; B Esmailzadeh; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

Review 3.  Implantable dual-chamber cardioverter-defibrillator-pacemaker.

Authors:  D Pfeiffer; M Mende; A Hagendorff
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

Review 4.  Peptide synthesis through evolution.

Authors:  K Tamura; R W Alexander
Journal:  Cell Mol Life Sci       Date:  2004-06       Impact factor: 9.261

5.  T wave pacing inducing electrical storm and multiple shocks in an ICD-recipient: a novel complication of the automatic gain control function.

Authors:  Simon Abou Jaoudé; Elie Salamé; Rabih Azar; Roland Kassab
Journal:  J Interv Card Electrophysiol       Date:  2003-12       Impact factor: 1.900

Review 6.  [Complications during exercise testing].

Authors:  R Berent; J Auer; S P von Duvillard; H Sinzinger; P Schmid
Journal:  Herz       Date:  2011-11-17       Impact factor: 1.443

7.  Incessant ventricular tachycardia, refractory to catheter ablation, in an ICD patient terminated by ICD lead extraction: a case report.

Authors:  Corinna Lenz; Thomas Dietze; Michael Möller; Wolfgang Schöbel; Jens Wicke; Hans-Jörg Kellner; Rainer Gradaus; Jörg Neuzner
Journal:  Clin Res Cardiol       Date:  2009-08-28       Impact factor: 5.460

8.  Case report: inappropriate discharge of an implantable cardioverter-defibrillator caused by the combined count criterion.

Authors:  C Wolpert; W Jung; S Spehl; T Korte; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-03       Impact factor: 1.900

Review 9.  Ventricular fibrillation induced by high-output ICD shock: report of cases and review of literature.

Authors:  Adil Sattar; Shmuel Inbar
Journal:  BMJ Case Rep       Date:  2017-07-13

10.  The precise timing of tachycardia entrainment is determined by the postpacing interval, the tachycardia cycle length, and the pacing rate: Theoretical insights and practical applications.

Authors:  Daniel W Kaiser; Henry H Hsia; Anne M Dubin; L Bing Liem; Mohan N Viswanathan; Paul C Zei; Paul J Wang; Sanjiv M Narayan; Mintu P Turakhia
Journal:  Heart Rhythm       Date:  2015-12-02       Impact factor: 6.343