Decay in quality of closed-chest compressions over time.

D Hightower1, S H Thomas, C K Stone, K Dunn, J A March.   

Abstract

STUDY
OBJECTIVE: To characterize fatigue-induced deterioration in the adequacy of closed-chest compressions performed over a period of 5 minutes and to determine whether CPR providers can recognize the effects of fatigue on compression adequacy.
DESIGN: Prospective evaluation of study subjects performing closed-chest compressions on an electronic mannequin that assesses compression placement and depth.
SETTING: Major resuscitation room in rural university hospital emergency department. PARTICIPANTS: Eleven experienced nursing assistants who regularly provide CPR in the ED.
RESULTS: Each study participant performed 5 minutes of closed-chest compressions. Compression adequacy (for placement and depth) was assessed with the mannequin and reported on an attached monitor out of view of the study subjects. Subjects were asked to verbally indicate the point during their 5-minute compression period at which they felt too fatigued to provide effective compressions (arbitrarily defined as a minimum of 90% of all compressions being judged correct by the mannequin). We used one-way repeated-measures ANOVA and regression analysis to determine whether compression adequacy diminished over time. ANOVA was also used to determine whether the total compressions performed per minute diminished over time. The percentage of correct chest compressions decreased significantly after 1 minute of compressions (P = .0001). We found 92.9% of compressions performed during minute 1 to be correct. The percentages for minutes 2 through 5 were as follows: 67.1%, 39.2%, 31.2%, and 18.0%. Regression analysis revealed a decrement in compression adequacy of 18.6% per minute after the first minute of compressions. The number of total compressions attempted per minute did not decrease (P = .98). Study subjects did not accurately identify the point during their 5-minute sessions at which their fatigue caused compressions to become impaired. Whereas mean compression adequacy declined below 90% after only 1 minute, the time of indicated fatigue was 253 +/- 40 seconds (mean +/- SD).
CONCLUSION: Although compression rate was maintained over time, chest compression quality declined significantly over the study period. Because CPR providers could not recognize their inability to provide proper compressions, cardiac arrest team leaders should carefully monitor compression adequacy during CPR to assure maximally effective care for patients receiving CPR.

Entities:  

Mesh:

Year:  1995        PMID: 7661418     DOI: 10.1016/s0196-0644(95)70076-5

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  48 in total

Review 1.  Cardiopulmonary resuscitation using electrically driven devices: a review.

Authors:  Anatol Prinzing; Stefan Eichhorn; Marcus-André Deutsch; Ruediger Lange; Markus Krane
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

2.  New strategies for cardiopulmonary resuscitation.

Authors:  Jonas A Cooper; Joshua M Cooper
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-02

3.  [Emergency physician and AutoPulse--a good duo in preclinical emergency services?: case example and report on experience].

Authors:  J-C Schewe; U Heister; A Hoeft; H Krep
Journal:  Anaesthesist       Date:  2008-06       Impact factor: 1.041

4.  Correlations between quality indexes of chest compression.

Authors:  Feng-Ling Zhang; Li Yan; Su-Fang Huang; Xiang-Jun Bai
Journal:  World J Emerg Med       Date:  2013

Review 5.  Mechanical cardiopulmonary resuscitation for patients with cardiac arrest.

Authors:  Lei Jiang; Jin-Song Zhang
Journal:  World J Emerg Med       Date:  2011

6.  Effects of a backboard, bed height, and operator position on compression depth during simulated resuscitation.

Authors:  Gavin D Perkins; Chris M Smith; Colette Augre; Michael Allan; Helen Rogers; Barney Stephenson; David R Thickett
Journal:  Intensive Care Med       Date:  2006-07-07       Impact factor: 17.440

7.  New Developments in Cardiac Arrest Management.

Authors:  Matthias L Riess
Journal:  Adv Anesth       Date:  2016

8.  Increasing CPR duration prior to first defibrillation does not improve return of spontaneous circulation or survival in a swine model of prolonged ventricular fibrillation.

Authors:  Jon C Rittenberger; Brian Suffoletto; David Salcido; Eric Logue; James J Menegazzi
Journal:  Resuscitation       Date:  2008-07-11       Impact factor: 5.262

9.  Work of CPR during two different compression to ventilation ratios with real-time feedback.

Authors:  Amy E Betz; Clifton W Callaway; David Hostler; Jon C Rittenberger
Journal:  Resuscitation       Date:  2008-08-06       Impact factor: 5.262

10.  Manual versus mechanical cardiopulmonary resuscitation. An experimental study in pigs.

Authors:  Qiuming Liao; Trygve Sjöberg; Audrius Paskevicius; Björn Wohlfart; Stig Steen
Journal:  BMC Cardiovasc Disord       Date:  2010-10-28       Impact factor: 2.298