[Emergency physician and AutoPulse--a good duo in preclinical emergency services?: case example and report on experience].

J-C Schewe1, U Heister, A Hoeft, H Krep.   

Abstract

Survival rates after cardiac arrest remain poor despite substantial efforts to advance the cardiopulmonary resuscitation algorithm in the last decades. Recent changes in the resuscitation guidelines in 2005 focused on minimizing interruptions during chest compressions. The aim to provide optimal chest compressions led to the development of automated mechanical chest compression devices, one of which is the AutoPulse resuscitation system. A case of successful use of the AutoPulse system in a 66-year-old patient with sudden cardiac arrest is presented and a review is given of more than 3 years experience in the routine use of this mechanical device for CPR in the emergency medical system in Bonn. Based on this experience, the AutoPulse system is considered to be a safe and effective technical advancement that under certain CPR conditions can be a helpful tool and provide an increased quality of chest compressions.

Entities:  

Mesh:

Year:  2008        PMID: 18446523     DOI: 10.1007/s00101-008-1376-0

Source DB:  PubMed          Journal:  Anaesthesist        ISSN: 0003-2417            Impact factor:   1.041


  29 in total

1.  Characteristics of fatal ambulance crashes in the United States: an 11-year retrospective analysis.

Authors:  C A Kahn; R G Pirrallo; E M Kuhn
Journal:  Prehosp Emerg Care       Date:  2001 Jul-Sep       Impact factor: 3.077

2.  Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest.

Authors:  Lars Wik; Jo Kramer-Johansen; Helge Myklebust; Hallstein Sørebø; Leif Svensson; Bob Fellows; Petter Andreas Steen
Journal:  JAMA       Date:  2005-01-19       Impact factor: 56.272

3.  Autopsy artifact created by the Revivant AutoPulse resuscitation device.

Authors:  Amy P Hart; Venus J Azar; Katherine R Hart; Boyd G Stephens
Journal:  J Forensic Sci       Date:  2005-01       Impact factor: 1.832

4.  2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Part 4: Advanced life support.

Authors: 
Journal:  Resuscitation       Date:  2005 Nov-Dec       Impact factor: 5.262

Review 5.  European Resuscitation Council guidelines for resuscitation 2005. Section 8. The ethics of resuscitation and end-of-life decisions.

Authors:  Peter J F Baskett; Petter A Steen; Leo Bossaert
Journal:  Resuscitation       Date:  2005-12       Impact factor: 5.262

6.  2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

Authors: 
Journal:  Circulation       Date:  2005-11-28       Impact factor: 29.690

7.  Out-of-hospital cardiopulmonary resuscitation with the AutoPulse system: a prospective observational study with a new load-distributing band chest compression device.

Authors:  Henning Krep; Mathias Mamier; Martin Breil; Ulrich Heister; Matthias Fischer; Andreas Hoeft
Journal:  Resuscitation       Date:  2007-01-24       Impact factor: 5.262

8.  Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation.

Authors:  Marcus Eng Hock Ong; Joseph P Ornato; David P Edwards; Harinder S Dhindsa; Al M Best; Caesar S Ines; Scott Hickey; Bryan Clark; Dean C Williams; Robert G Powell; Jerry L Overton; Mary Ann Peberdy
Journal:  JAMA       Date:  2006-06-14       Impact factor: 56.272

9.  Comparison of mechanical techniques of cardiopulmonary resuscitation: survival and neurologic outcome in dogs.

Authors:  K B Kern; A B Carter; R L Showen; W D Voorhees; C F Babbs; W A Tacker; G A Ewy
Journal:  Am J Emerg Med       Date:  1987-05       Impact factor: 2.469

10.  Decay in quality of closed-chest compressions over time.

Authors:  D Hightower; S H Thomas; C K Stone; K Dunn; J A March
Journal:  Ann Emerg Med       Date:  1995-09       Impact factor: 5.721

View more
  1 in total

Review 1.  [Mechanical resuscitation assist devices].

Authors:  M Fischer; M Breil; M Ihli; M Messelken; S Rauch; J-C Schewe
Journal:  Anaesthesist       Date:  2014-03       Impact factor: 1.041

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.