Literature DB >> 7646210

Tricuspid valve replacement: porcine bioprostheses and mechanical prostheses.

A I Munro1, W R Jamieson, G F Tyers, E Germann.   

Abstract

The clinical performance of tricuspid valve replacement with bioprostheses and mechanical prostheses was assessed in a series of 5,489 total valve replacement operations performed from 1975 to 1992. There were 97 (1.8%) tricuspid valve replacements in 94 patients (16 men, 78 women) with a mean age of 55.4 +/- 13.8 years. Bioprostheses (mean patient age, 55.9 +/- 14.1 years) were used in 83 operations and mechanical prostheses (mean patient age, 52.1 +/- 11.9 years) were used in 14 operations. There were 30 isolated tricuspid valve replacements and 67 tricuspid valve replacements incorporated in multiple valve replacements. The total cumulative follow-up was 360 patient-years (bioprostheses, 321 years; mechanical prostheses, 39 years) (96.8% complete). The mean follow-up was 3.7 years (bioprostheses, 3.9 years; mechanical prostheses, 2.8 years) (p = not significant). The early mortality was 14.4% (bioprostheses, 14.5%; mechanical prostheses, 14.3%) (p = not significant) (isolated replacement, 13.3%; multiple replacement, 14.9%). The late mortality was 9.2% per patient-year (isolated replacement, 12.2% per patient-year; multiple replacement, 7.9% per patient-year). The freedom from structural valve deterioration at 5 and 7 years was 100% for mechanical prostheses and 97.1% +/- 2.9% for bioprostheses (p = not significant). For isolated tricuspid valve replacement, the freedom from structural valve deterioration for bioprostheses was 90.9% +/- 8.7% at 5 years and at 7 years (p = not significant). For the mechanical prostheses, the freedom was 100%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7646210     DOI: 10.1016/0003-4975(95)00271-l

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  11 in total

1.  Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

Authors:  J M García Páez; E Jorge Herrero; M Martín Maestro; A Rocha; B Arenaz; J L Castillo-Olivares; A Carrera Sanmartín; A Cordon; I Millán
Journal:  J Mater Sci Mater Med       Date:  2003-05       Impact factor: 3.896

2.  A new method for selecting calf pericardium for use in cardiac bioprostheses on the basis of morphological and mechanical criteria.

Authors:  J M García Páez; E Jorge-Herrero; A Carrera; I Millán; A Rocha; A Cordón; J Salvador; N Sainz; J Méndez; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2001-08       Impact factor: 3.896

3.  Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing. Part II. Porcine pericardium.

Authors:  J M García Páez; E Jorge; A Rocha; J L Castillo-Olivares; I Millan; A Carrera; A Cordon; G Tellez; R Burgos
Journal:  J Mater Sci Mater Med       Date:  2002-05       Impact factor: 3.896

4.  Long-term results of porcine bioprostheses in the tricuspid position.

Authors:  K Kuwaki; K Komatsu; K Morishita; M Tsukamoto; T Abe
Journal:  Surg Today       Date:  1998       Impact factor: 2.549

Review 5.  Evidence-based surgical management of acquired tricuspid valve disease.

Authors:  Sung Ho Shinn; Hartzell V Schaff
Journal:  Nat Rev Cardiol       Date:  2013-02-12       Impact factor: 32.419

6.  Surgery for tricuspid valve endocarditis: a selective approach.

Authors:  A Renzulli; M De Feo; A Carozza; A Della Corte; R Gregorio; G Ismeno; M Cotrufo
Journal:  Heart Vessels       Date:  1999       Impact factor: 2.037

7.  Tricuspid repair for infective endocarditis: clinical and echocardiographic results.

Authors:  A Carozza; A Renzulli; M De Feo; G Ismeno; A Della Corte; G Dialetto; M Cotrufo
Journal:  Tex Heart Inst J       Date:  2001

8.  Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing: Part I. Calf pericardium.

Authors:  J M García Páez; E Jorge; A Rocha; M Maestro; J L Castillo-Olivares; I Millan; A Carrera; A Cordon; G Tellez; R Burgos
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

9.  Hysteresis of a biomaterial: influence of sutures and biological adhesives.

Authors:  J M García Páez; A Carrera; E Jorge; I Millán; A Cordón; A Rocha; M Maestro; J L Castillo-Olivares
Journal:  J Mater Sci Mater Med       Date:  2006-11-30       Impact factor: 4.727

10.  Valvectomy versus replacement for the surgical treatment of infective tricuspid valve endocarditis: a systematic review and meta-analysis.

Authors:  Jessica G Y Luc; Jae-Hwan Choi; Karishma Kodia; Matthew P Weber; Dylan P Horan; Elizabeth J Maynes; Laura A Carlson; H Todd Massey; John W Entwistle; Rohinton J Morris; Vakhtang Tchantchaleishvili
Journal:  Ann Cardiothorac Surg       Date:  2019-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.