Literature DB >> 7644959

Morphometric evaluation of the first sacral vertebra and the projection of its pedicle on the posterior aspect of the sacrum.

R Xu1, N A Ebraheim, R A Yeasting, F Y Wong, W T Jackson.   

Abstract

STUDY
DESIGN: This study directly measured the dimensions of the first sacral vertebra based on dry bony specimens.
OBJECTIVES: To measure the dimensions of the S1 pedicle, vertebral body, and spinal canal, and determine the projections of the S1 pedicle on the posterior aspect of the sacrum. SUMMARY OF BACKGROUND DATA: Sacral screw fixation remains a challenging clinical problem because of the unique anatomy of the first sacral vertebra. The anatomic data of S1 have rarely been described in the literature.
METHODS: Sacrums from 50 carefully prepared bony spines were used. Linear measurements included the dimensions of the vertebral body, spinal canal, and pedicle. Pedicle width was measured in two segments, pedicle zones 1 and 2. Angular measurements of the pedicle relative to the sagittal plane were also included.
RESULTS: In pedicle zone 1, the average medial angle of the pedicles was 10.2 degrees for men and 10.7 degrees for women, average width was 10.9 mm for men and 10.4 mm for women, average length of the pedicles was 34.6 mm for men and 34.9 mm for women. In pedicle zone 2, the average medial angle of the pedicles was 39.4 degrees for both men and women, average width was 15.6 mm for men and 14.7 mm for women, average length of the pedicles was 43.7 mm for men, and 41.7 mm for women. The projections of pedicle zones 1 and 2 on the posterior aspect of S1 were determined.
CONCLUSIONS: The investigators proposed the concept of pedicle zones 1 and 2. The safer area for S1 pedicle screw insertion was found in pedicle zone 2.

Entities:  

Mesh:

Year:  1995        PMID: 7644959     DOI: 10.1097/00007632-199504150-00010

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  11 in total

1.  A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis.

Authors:  Mun Keong Kwan; Amit Jeffry; Chris Yin Wei Chan; Lim Beng Saw
Journal:  Surg Radiol Anat       Date:  2011-12-23       Impact factor: 1.246

2.  A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

Authors:  Hansrudi Noser; Florian Radetzki; Karsten Stock; Thomas Mendel
Journal:  J Digit Imaging       Date:  2011-08       Impact factor: 4.056

3.  Morphometry of the sacrum for clinical use.

Authors:  H Başaloğlu; M Turgut; F A Taşer; T Ceylan; H K Başaloğlu; A A Ceylan
Journal:  Surg Radiol Anat       Date:  2005-10-07       Impact factor: 1.246

4.  [Bony sacroiliac corridor. A virtual volume model for the accurate insertion of transarticular screws].

Authors:  T Mendel; K Appelt; P Kuhn; N Suhm
Journal:  Unfallchirurg       Date:  2008-01       Impact factor: 1.000

5.  Neurovascular risks of sacral screws with bicortical purchase: an anatomical study.

Authors:  Ipek Ergur; Omer Akcali; Amac Kiray; Can Kosay; Hamid Tayefi
Journal:  Eur Spine J       Date:  2007-02-14       Impact factor: 3.134

6.  Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study.

Authors:  Akira Matsuoka; Tomoaki Toyone; Ichiro Okano; Yoshifumi Kudo; Koji Ishikawa; Hiroshi Maruyama; Tomoyuki Ozawa; Toshiyuki Shirahata; Katsunori Inagaki
Journal:  BMC Musculoskelet Disord       Date:  2022-07-05       Impact factor: 2.562

7.  L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws.

Authors:  Masahiro Inoue; Gen Inoue; Tomoyuki Ozawa; Masayuki Miyagi; Hiroto Kamoda; Tetsuhiro Ishikawa; Miyako Suzuki; Yoshihiro Sakuma; Yasuhiro Oikawa; Kazuyo Yamauchi; Sumihisa Orita; Masashi Takaso; Tomoaki Toyone; Kazuhisa Takahashi; Seiji Ohtori
Journal:  Eur Spine J       Date:  2012-12-28       Impact factor: 3.134

8.  Reinforcement of lumbosacral instrumentation using S1-pedicle screws combined with S2-alar screws.

Authors:  H Koller; J Zenner; A Hempfing; L Ferraris; O Meier
Journal:  Oper Orthop Traumatol       Date:  2013-06       Impact factor: 1.154

9.  Anatomic Parameters for Instrumentation of the Sacrum and Pelvis: A Systematic Review of the Literature.

Authors:  Yoshihiro Katsuura; Eric Chang; Shahbaaz A Sabri; Warren E Gardner; Jesse F Doty
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-08-02

10.  Biomechanical Analysis of an S1 Pedicle Screw Salvage Technique via a Superior Articulating Process Entry Point.

Authors:  Yu-Po Lee; Hansel E Ihn; Michelle H McGarry; Saifal-Deen Farhan; Nitin Bhatia; Thay Q Lee
Journal:  Spine (Phila Pa 1976)       Date:  2016-07-01       Impact factor: 3.241

View more