Literature DB >> 7641755

Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.

G J Hademenos1, M Dahlbom, E J Hoffman.   

Abstract

A spilldown correction method is proposed for the thallium-201 window image in simultaneous dual-isotope technetium-99m/thallium-201 single-photon emission tomographic (SPET) imaging based on a single acquisition into three energy windows. In this method, images are simultaneously acquired in two standard energy windows over the 99mTc and 201Tl photopeak regions and a third spilldown window adjacent to the 201Tl window. Using a Monte Carlo simulation of SPET, the fractional amount of 99mTc and 201Tl spilldown in the 201Tl window with respect to the total counts from the spilldown window, k12, was calculated for simulated images of point sources at varying depths within a water-filled elliptical tub phantom. When applied to experimental acquisitions, k12, multiplied by the total counts from the spilldown window, is then subtracted from the 201Tl window image to produce the corrected image. However, for successful applications in SPET, k12 must be determined on a projection-by-projection basis since k12 is depth dependent. Thus, a regression relation was obtained between k12 and the total count ratio of the spilldown to 99mTc windows, k23. The spilldown correction method was applied to 201Tl photopeak images of an extended source distribution in uniform and nonuniform attenuating media with dual-isotope 99mTc/201Tl and single-isotope 201Tl. A marked improvement in image contrast was observed between the corrected and uncorrected 201Tl window images. The average count ratio of uncorrected dual-isotope 201Tl/single-isotope 201Tl was 3.08 for uniform and 2.99 for non-uniform attenuating media.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7641755     DOI: 10.1007/bf00839061

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Simultaneous acquisition of emission and transmission data for improved thallium-201 cardiac SPECT imaging using a technetium-99m transmission source.

Authors:  E C Frey; B M Tsui; J R Perry
Journal:  J Nucl Med       Date:  1992-12       Impact factor: 10.057

2.  Simultaneous dual-isotope SPECT imaging for the detection and characterization of parathyroid pathology.

Authors:  D R Neumann
Journal:  J Nucl Med       Date:  1992-01       Impact factor: 10.057

3.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

4.  Improved SPECT using simultaneous emission and transmission tomography.

Authors:  D L Bailey; B F Hutton; P J Walker
Journal:  J Nucl Med       Date:  1987-05       Impact factor: 10.057

5.  A new dual-isotope convolution cross-talk correction method: a Tl-201/Tc-99m SPECT cardiac phantom study.

Authors:  K Knesaurek
Journal:  Med Phys       Date:  1994-10       Impact factor: 4.071

6.  Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT.

Authors:  H Kiat; G Germano; J Friedman; K Van Train; G Silagan; F P Wang; J Maddahi; D Berman
Journal:  J Nucl Med       Date:  1994-04       Impact factor: 10.057

7.  Parathyroid imaging by Tc/Tl scintigraphy.

Authors:  D Sandrock; M J Merino; J A Norton; R D Neumann
Journal:  Eur J Nucl Med       Date:  1990

8.  Radiation necrosis vs high-grade recurrent glioma: differentiation by using dual-isotope SPECT with 201TI and 99mTc-HMPAO.

Authors:  R B Schwartz; P A Carvalho; E Alexander; J S Loeffler; R Folkerth; B L Holman
Journal:  AJNR Am J Neuroradiol       Date:  1991 Nov-Dec       Impact factor: 3.825

9.  Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.

Authors:  D S Berman; H Kiat; J D Friedman; F P Wang; K van Train; L Matzer; J Maddahi; G Germano
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

10.  Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease.

Authors:  J C Maublant; X Marcaggi; J R Lusson; J Y Boire; J C Cauvin; P Jacob; A Veyre; J Cassagnes
Journal:  Am J Cardiol       Date:  1992-01-15       Impact factor: 2.778

View more
  4 in total

1.  Monte Carlo-based down-scatter correction of SPECT attenuation maps.

Authors:  Tomislav Bokulić; Brendan Vastenhouw; Hugo W A M de Jong; Alice J van Dongen; Peter P van Rijk; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-18       Impact factor: 9.236

2.  Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Authors:  P Hannequin; P Weinmann; J Mas; S Vinot
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

3.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

4.  Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner.

Authors:  Krzysztof Kacperski; Kjell Erlandsson; Simona Ben-Haim; Brian F Hutton
Journal:  Phys Med Biol       Date:  2011-02-11       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.