Literature DB >> 7639116

Quantitative analysis of trabecular microstructure by 400 MHz nuclear magnetic resonance imaging.

H W Chung1, F W Wehrli, J L Williams, S D Kugelmass, S L Wehrli.   

Abstract

A new approach for the quantitative analysis of trabecular microstructure, based on high-field proton nuclear magnetic resonance (NMR) imaging, is presented. NMR is ideal because it provides high contrast between the marrow proton signal and the bone, which appears with background intensity. Images from 1 cm3 defatted specimens of trabecular bone, suspended in water doped with 1 mM Gd(DTPA) to shorten T1 to about 300 ms, can be obtained at a resolution on the order of 30-50 microns and slice thickness of 150 microns, in 10 minutes at 400 MHz proton frequency. Digital image processing algorithms were designed and evaluated for the measurement of bone area fraction, perimeter length, mean trabecular thickness, and separation. Bone area fraction derived from the NMR images was found to be in excellent agreement with bone volume fraction measured independently (slope = 0.96, r2 = 0.924, p < 0.0001). Errors in the mean trabecular thickness and separation were < 6%. The effects of finite imaging slice thickness and signal-to-noise ratio (SNR) were also evaluated. The data suggest a resolution of 50 x 50 x 200 microns 3 and an SNR on the order of 10 to provide safe margins for precise and accurate structural analysis by means of the algorithms presented in this paper. The method allows simultaneous measurement at multiple locations within the specimen volume without the need for physical sectioning.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7639116     DOI: 10.1002/jbmr.5650100518

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  9 in total

Review 1.  Methods for assessing bone quality: a review.

Authors:  Eve Donnelly
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Cylinders or walls? A new computational model to estimate the MR transverse relaxation rate dependence on trabecular bone architecture.

Authors:  Bernd Müller-Bierl; Olivia Louis; Yves Fierens; Nico Buls; Robert Luypaert; Johan de Mey
Journal:  MAGMA       Date:  2013-09-06       Impact factor: 2.310

Review 3.  Microarchitectural changes in the aging skeleton.

Authors:  Yankel Gabet; Itai Bab
Journal:  Curr Osteoporos Rep       Date:  2011-12       Impact factor: 5.096

4.  Advances in the noninvasive assessment of bone density, quality, and structure.

Authors:  H K Genant; T F Lang; K Engelke; T Fuerst; C Glüer; S Majumdar; M Jergas
Journal:  Calcif Tissue Int       Date:  1996       Impact factor: 4.333

5.  Magnetic resonance imaging of trabecular bone structure in the distal radius: relationship with X-ray tomographic microscopy and biomechanics.

Authors:  S Majumdar; D Newitt; A Mathur; D Osman; A Gies; E Chiu; J Lotz; J Kinney; H Genant
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

Review 6.  Imaging technologies for assessment of skeletal health in men.

Authors:  E Michael Lewiecki
Journal:  Curr Osteoporos Rep       Date:  2013-03       Impact factor: 5.096

Review 7.  Noninvasive assessment of bone structure.

Authors:  Tamara J Vokes; Murray J Favus
Journal:  Curr Osteoporos Rep       Date:  2003-06       Impact factor: 5.096

8.  Implications of noise and resolution on mechanical properties of trabecular bone estimated by image-based finite-element analysis.

Authors:  Chamith S Rajapakse; Jeremy Magland; X Henry Zhang; X Sherry Liu; Suzanne L Wehrli; X Edward Guo; Felix W Wehrli
Journal:  J Orthop Res       Date:  2009-10       Impact factor: 3.494

9.  First meeting on bone quality, Abbaye des Vaux de Cernay, France, 15-16 June 2006: Bone architecture.

Authors: 
Journal:  Osteoporos Int       Date:  2007-06       Impact factor: 5.071

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.